LW G6CP-EAFA-JKQL-1-Z OSRAM Opto Semiconductors Inc, LW G6CP-EAFA-JKQL-1-Z Datasheet

no-image

LW G6CP-EAFA-JKQL-1-Z

Manufacturer Part Number
LW G6CP-EAFA-JKQL-1-Z
Description
LED TOPLED ADV PWR WHT 6PLCC
Manufacturer
OSRAM Opto Semiconductors Inc
Series
TOPLEDr
Datasheet

Specifications of LW G6CP-EAFA-JKQL-1-Z

Color
White, Cool
Current - Test
140mA
Luminous Flux @ Current - Test
25lm
Current - Max
250mA
Lumens @ Current - Max
26lm
Lumens/watt @ Current - Test
50lm/W
Voltage - Forward (vf) Typ
3.6V
Wavelength
5600K
Lens Style/size
Round, 2.6mm
Viewing Angle
120°
Mounting Type
Surface Mount
Package / Case
6-LCC (J-Lead)
Power Rating
1075 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q65110A8947
Advanced Power TOPLED with Chip Level Conversion (CLC)
Enhanced optical Power LED (ThinGaN)
Lead (Pb) Free Product - RoHS Compliant
LW G6CP
Released
OS-IN-2009-009
Besondere Merkmale
• Gehäusetyp: weißes P-LCC-6 Gehäuse,
• Besonderheit des Bauteils: sehr kleiner
• Farbort: x = 0,34, y = 0,34 nach
• typische Farbtemperatur: 5600 K
• Farbwiedergabeindex: 80
• Abstrahlwinkel: Lambertscher Strahler (120°)
• Technologie: ThinGaN
• optischer Wirkungsgrad: 46 lm/W
• Gruppierungsparameter: Lichtstärke,
• Verarbeitungsmethode: für alle
• Lötmethode: Reflow Löten
• Vorbehandlung: nach JEDEC Level 2
• Gurtung: 12 mm Gurt mit 1000/Rolle,
• ESD-Festigkeit: ESD-sicher bis 2 kV nach
Anwendungen
• Außen- und Innenbeleuchtung im Automobilbe-
• Hinterleuchtung (Werbebeleuchtung,
• Leselampen (Flugzeug, Auto, Bus)
• Ersatz von Kleinst-Glühlampen
• Display Hinterleuchtung mit hohem
• Dekorative Beleuchtung
• Signal- und Symbolleuchten zur Orientierung
• Markierungsbeleuchtung (z.B. Stufen, Flucht-
2009-07-21
klarer Silikon - Verguss
thermischer Widerstand, dadurch sehr hohe
Lichtleistung möglich
CIE 1931 (weiß)
Farbort, Durchlassspannung
SMT-Bestücktechniken geeignet
ø180 mm
JESD22-A114-D
reich (z.B. Tagfahrlicht, Scheinwerfer, Instru-
mentenbeleuchtung)
Allgemeinbeleuchtung)
Helligkeitsbedarf z. B. TFT
wege, u.ä.)
1
Features
• package: white P-LCC-6 package, clear
• feature of the device: very low thermal
• color coordinates: x = 0.34, y = 0.34 acc. to
• typ. color temperature: 5600 K
• color reproduction index: 80
• viewing angle: Lambertian Emitter (120°)
• technology: ThinGaN
• optical efficiency: 46 lm/W
• grouping parameter: luminous intensity,
• assembly methods: suitable for all
• soldering methods: reflow soldering
• preconditioning: acc. to JEDEC Level 2
• taping: 12 mm tape with 1000/reel, ø180 mm
• ESD-withstand voltage: up to 2 kV acc. to
Applications
• exterior and interior automotive lighting
• backlighting (illuminated advertising, general
• reading lamps (aircraft, car, bus)
• substitution of micro incandescent lamps
• display backlight where high brightness is
• decorative and entertainment lighting
• signal and symbol luminaire for orientation
• marker lights (e.g. steps, exit ways, etc.)
silicone resin
resistance; high optical power
CIE 1931 (white)
color coordinates, forward voltage
SMT assembly methods
JESD22-A114-D
(e.g. day time running light, front light,
dashboard backlighting)
lighting)
required e.g. TFT

Related parts for LW G6CP-EAFA-JKQL-1-Z

LW G6CP-EAFA-JKQL-1-Z Summary of contents

Page 1

... Advanced Power TOPLED with Chip Level Conversion (CLC) Enhanced optical Power LED (ThinGaN) Lead (Pb) Free Product - RoHS Compliant LW G6CP Released OS-IN-2009-009 Besondere Merkmale • Gehäusetyp: weißes P-LCC-6 Gehäuse, klarer Silikon - Verguss • Besonderheit des Bauteils: sehr kleiner thermischer Widerstand, dadurch sehr hohe Lichtleistung mö ...

Page 2

... The above Type Numbers represent the order groups which include only a few brightness groups (see page 7 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LW G6CP-EAFA-JKQL-1 means that only one group EA will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. ...

Page 3

... Symbol Wert Symbol Value T – 40 … + 125 op T – 40 … + 125 stg T >150 for short j term applications T + 150 j (min (max.) 250 F I 750 FM V not designed for R reverse operation P 1075 tot G6CP Einheit Unit °C °C °C ° K/W K/W ...

Page 4

... V (min (typ (max (typ.) TC (typ.) TC (typ η (typ.) opt 4 Wert Value 0.34* 0.34* 120 2.9* 3.6 4.1 not designed for reverse operation see page 9 x see page 9 y see page G6CP Einheit Unit – – Grad deg μ mV/K lm/W ...

Page 5

... 0.27 JK 0.25 0.23 0.21 0.19 Cx 0,3288 0,3288 0,3386 0,3386 0,3288 0,3288 0,3386 0,3386 0,3386 0,3386 0,3484 0,3484 0,3386 0,3386 0,3484 0,3484 LW G6CP OHL04146 Cy 0,3081 0,3282 0,3426 0,3235 0,3282 0,3453 0,3591 0,3426 0,3235 0,3426 0,3571 0,3388 0,3426 0,3591 0,373 0,3571 ...

Page 6

... Cy Group 0,297 PK 0,3131 0,2956 0,284 0,312 PL 0,3302 0,3131 0,297 0,3131 QK 0,3282 0,3081 0,2956 0,3302 QL 0,3452 0,3282 0,3131 6 LW G6CP Cx Cy 0,3484 0,3388 0,3484 0,3571 0,3582 0,3715 0,3582 0,3542 0,3484 0,3571 0,3484 0,373 0,3582 0,3792 0,3582 0,3715 0,3582 0,3542 0,3582 0,3715 0,368 ...

Page 7

... Luminous Intensity I (mcd) V 7100 ... 9000 9000 ... 11200 11200 ... 14000 6) Seite 18 Durchlassspannung Forward voltage max. 3.2 3.5 3.8 4.1 Farbortgruppe Chromaticity Coordinate Group G6CP 2) Seite 18 Lichtstrom 2) page 18 Luminous Flux Φ (mlm) V 24100 (typ.) 30300 (typ.) 37800 (typ.) Einheit Unit Durchlassspannungsgruppe Forward Voltage Group 5 ...

Page 8

... Seite 18 2) page 18 V λ 500 550 600 20˚ 10˚ 0˚ ϕ 1.0 0.8 0.6 0.4 0.2 0 0.6 0.4 0˚ 8 650 700 750 20˚ 40˚ 60˚ 80˚ LW G6CP OHL03949 nm 800 λ OHL01660 100˚ 120˚ ...

Page 9

... F A 0.035 Δ Δ Cx, Cy 0.020 0.015 0.010 0.005 0 -0.005 -0.010 -0.015 -0.020 -0.025 -0.030 0 100 200 2009-07-21 Relative Lichtstrom Relative Luminous Flux Ι / Ι V OHL02767 4.2 4 page 18 OHL03950 Cx Cy 300 400 mA 500 Seite page 18 (140 mA ° (140 mA G6CP OHL02768 ...

Page 10

... Seite 18 Relative Lichtstärke Relative Luminous Intensity ); I = 140 OHL02772 40 60 ˚C 100 page 18 OHL03996 ˚C 100 Seite 18 I (25 ° 140 1 (25 ˚C) 1.0 0.8 0.6 0.4 0.2 0 -60 -40 - G6CP 2) page 18 OHL02725 40 60 ˚C 100 T j ...

Page 11

... parameter ° 0.7 0.6 0.5 0.4 0.3 0.2 0 G6CP 2) Seite 18 Einheit Unit Betriebsstunden operating hours Betriebsstunden operating hours Betriebsstunden operating hours OHL03512 0.005 0.01 0.02 0.033 0.05 0.1 0.2 0 ...

Page 12

... Seite 18 Maßzeichnung 8) page 18 Package Outlines Kathodenkennung: Cathode mark: Gewicht / Approx. weight: Gurtung / Polarität und Lage Method of Taping / Polarity and Orientation 2009-07-21 Markierung mark Seite 18 Verpackungseinheit 1000/Rolle, ø180 mm 8) page 18 Packing unit 1000/reel, ø180 G6CP ...

Page 13

... Anm.: Das Gehäuse ist für Ultraschallreinigung nicht geeignet Note: Package not suitalbe for ultra sonic cleaning 2009-07- Seite page 18 0.8 (0.031) 2 0.35 (0.014) 0.6 (0.024) Lötstopplack Solder resist 13 Reflow Löten Reflow Soldering 0.8 (0.031) 0.35 (0.014) OHLP4927 LW G6CP Package marking ...

Page 14

... B) OHLA0687 260 ˚C 245 ˚C 235 ˚ min 30 s max Ramp Down 6 K/s (max) 100 s max 200 250 s t Normalkurve standard curve Grenzkurven limit curves 2 K/s 150 200 t LW G6CP +0 ˚C -5 ˚C ±5 ˚C +5 ˚C -0 ˚C 300 OHLY0598 s 250 ...

Page 15

... GROUP Forward Voltage Group Wavelength Group Brightness Group OHA12043 Label Direction of unreeling Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: 160 mm Trailer: 160 1.5 + 0.1 1.75 ± 0.1 (0.059 + 0.004) (0.069 ± 0.004) LW G6CP OHAY0324 F 5.5 ± 0.05 (0.217 ± 0.002 max 18.4 (0.724) ...

Page 16

... If dry. adequately desiccant change still parts 5% wet, If MIL-I-8835 Indicator Humidity Desiccant Barcode label Länge / length ± ± 200 5 (7,874 0,1968) 16 Humidity indicator Barcode label OHA00539 Barcode label Packing Sealing label Höhe / height ± ± (1,1811 0,1968) LW G6CP OHA02044 ...

Page 17

... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 10) page 18 components may only be used in life-support devices or systems OSRAM OS. 2009-07-21 11) page 18 with the express written approval G6CP Date of change 2007-07-31 2008-03-19 2009-02-03 2009-04-15 2009-06-26 2009-07-21 ...

Page 18

... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health and the life of the user may be endangered. 18 figures. These do not If requested, e.g. because application note on our LW G6CP necessarily of technical web site ...

Related keywords