LUW C9EP-N4N6-EG-Z OSRAM Opto Semiconductors Inc, LUW C9EP-N4N6-EG-Z Datasheet

LED CERAMOS WHITE 6500K SMD

LUW C9EP-N4N6-EG-Z

Manufacturer Part Number
LUW C9EP-N4N6-EG-Z
Description
LED CERAMOS WHITE 6500K SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
CERAMOSr
Type
Ceramos LEDsr
Datasheet

Specifications of LUW C9EP-N4N6-EG-Z

Viewing Angle
120°
Color
White, Cool
Current - Test
500mA
Luminous Flux @ Current - Test
90lm
Current - Max
500mA
Lumens @ Current - Max
90lm
Lumens/watt @ Current - Test
53lm/W
Voltage - Forward (vf) Typ
3.4V
Wavelength
6500K
Lens Style/size
Rectangle with Flat Top
Mounting Type
Surface Mount
Package / Case
2.10mm L x 1.65mm W x 0.75mm H
Illumination Color
Ultra White
Wavelength/color Temperature
6500 K
Luminous Flux
84 lm
Luminous Intensity
28 cd
Operating Voltage
3.4 V
Operating Current
500 mA
Minimum Operating Temperature
- 40 C
Maximum Operating Temperature
+ 85 C
Lens Shape
Rectangular
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
475-2826-2
Q65110A7878
Ceramic TopLooker for high light output,
designed for camera flash application
Lead (Pb) Free Product - RoHS Compliant
LUW C9EP
CERAMOS
Released
Besondere Merkmale
• Gehäusetyp: SMD Keramik Gehäuse mit
• Typischer Lichtstrom: 84 lm bei 500 mA
• Besonderheit des Bauteils: hocheffiziente
• Farbort: x = 0,31, y = 0,32 nach
• typische Farbtemperatur: 6500 K
• Abstrahlwinkel: Lambertscher Strahler 120°
• Technologie: ThinGaN
• optischer Wirkungsgrad: 49 lm/W bei
• Gruppierungsparameter: Lichtstrom, Farbort
• Lötmethode: Reflow Löten
• Vorbehandlung: nach JEDEC Level 2
• Gurtung: 8-mm Gurt mit 4000/Rolle, ø180 mm
• ESD-Festigkeit:
Anwendungen
• Blitzlicht
• Taschenlampe
• Videoleuchte
• Fassadenbeleuchtung im Innenbereich
• Display Hinterleuchtung mit hohem
2009-09-22
diffusem Silikonverguss
Lichtquelle bei geringem Platzbedarf
CIE 1931 (weiß)
500 mA
2 kV nach JESD22-A114-D
8 kV nach IEC 61000-4-2, level 4 (contact
discharge)
Helligkeitsbedarf z. B. TFT
TM
®
1
Features
• package: SMD ceramic package with diffused
• typical Luminous Flux: 84 lm at 500 mA
• feature of the device: high efficient lightsource
• color coordinates: x = 0.31, y = 0.32 acc. to
• typ. color temperature: 6500 K
• viewing angle: Lambertian Emitter 120°
• technology: ThinGaN
• optical efficiency: 49 lm/W at 500 mA
• grouping parameter: luminous flux,
• soldering methods: reflow soldering
• preconditioning: acc. to JEDEC Level 2
• taping: 8 mm tape with 4000/reel, ø180 mm
• ESD-withstand voltage:
Applications
• camera flash light / strobe light
• torch light
• video light
• indoor commercial and residential architectural
silicone resin
at small dimensions
CIE 1931 (white)
color coordinates
2 kV acc. to JESD22-A114-D
8 kV acc. to IEC 61000-4-2, level 4 (contact
discharge).
lighting
display backlight where high brightness is
required e.g. TFT
®

Related parts for LUW C9EP-N4N6-EG-Z

LUW C9EP-N4N6-EG-Z Summary of contents

Page 1

... Ceramic TopLooker for high light output, designed for camera flash application Lead (Pb) Free Product - RoHS Compliant LUW C9EP TM CERAMOS Released Besondere Merkmale • Gehäusetyp: SMD Keramik Gehäuse mit diffusem Silikonverguss • Typischer Lichtstrom bei 500 mA • Besonderheit des Bauteils: hocheffiziente Lichtquelle bei geringem Platzbedarf • ...

Page 2

... The above Type Numbers represent the order groups which include only a few brightness groups (see page 6 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LUW C9EP-N4N6-EG means that only one group N4 will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. ...

Page 3

... A Sperrspannung Reverse voltage ( T =25°C) A 2009-09-22 Symbol Wert Symbol Value T – 40 … + 100 op T – 40 … – 40 … + 100 stg T 175 j (min.) I 100 F (max.) 500 I 1000 FM V not designed for R reverse operation 3 LUW C9EP Einheit Unit °C °C °C ° ...

Page 4

... Seite 18 (typ page 18 ϕ (typ (min (typ (max (max.) R η (typ.) opt R (typ (max LUW C9EP Wert Einheit Value Unit 0.31 – 0.32 – 120 Grad deg. 2.8 V 3.4 V 4.0 V not designed for μ reverse operation A 49 lm/W 28 K/W 34* K/W ...

Page 5

... Cy 0.42 0.41 0.40 0.39 0.38 0.37 0.36 0.35 F 0.34 + 0.33 0.32 E 0.31 0.30 0.29 0.28 0.27 Gruppe Cx Group G 0.350 0.347 0.337 0.328 0.346 LUW C9EP G Cx OHA03750 Cy 0.405 0.373 0.352 0.387 0.423 ...

Page 6

... Note: No packing unit / tape ever contains more than one brightness group. 2009-09-22 1) Seite 18 Lichtstärke 1) page 18 Luminous Intensity Φ (lm) V 75.0 ... 82.0 82.0 ... 97.0 97.0 ... 105.0 Farbortgruppe Chromaticity Coordinate Group E 6 LUW C9EP 2) Seite 18 Lichtstrom 2) page 18 Luminous Flux I (cd) V 26.0 (typ.) 30.0 (typ.) 34.0 (typ.) ...

Page 7

... F [V] typ. max. 3.2 3.7 3.4 4.0 3.6 4.3 3.8 4.8 2)page 18 (typ [cd] 21.5 28.0 35.5 45.0 2) page 18 median Lifetime >30.000 7 Flash Duration Flash Interval (T = 25°C) a [ms] [ 500 3 300 3 2)page 18 Phiv (typ.) [lm] 62.0 84.0 102.0 130.0 Unit Flashes LUW C9EP ...

Page 8

... Seite 18 2) page 18 500 550 20˚ 10˚ 0˚ ϕ 1.0 0.8 0.6 0.4 0.2 0 0.6 0.4 0˚ λ 600 650 700 20˚ 40˚ 60˚ 80˚ LUW C9EP OHL13926 nm 750 λ OHL01660 100˚ 120˚ ...

Page 9

... Cx, Cy 0.020 0.015 Cy 0.010 Cx 0.005 0 -0.005 -0.010 0 100 200 300 400 500 600 2009-09-22 Relative Lichtstrom Relative Luminous Flux Φ V OHL02520 Φ 3.5 4 Seite 18 OHL02866 mA 800 Seite page 18 Φ / (500 mA ° Φ V (500 mA LUW C9EP OHL13528 ...

Page 10

... Seite 18 Relative Lichtstrom Relative Luminous Flux Φ 500 OHL03676 60 80 100 ˚C 140 Seite 18 OHL03786 ˚C 140 Seite 18 2) page 18 Φ / (25 ° 500 1.10 Φ V Φ (25 ˚C) V 1.00 0.95 0.90 0.85 0.80 0.75 0.70 -40 - LUW C9EP OHL04067 ˚C 120 T j ...

Page 11

... Lebensdauer median Lifetime >100 = 250mA ’000 = 25°C A >100 = 500 mA ’000 = 85° parameter 1.1 T 1.0 0.9 0.8 0.7 0.6 0.5 0 LUW C9EP 2) Seite 17 Einheit Unit Betriebsstunden operating hours Betriebsstunden operating hours °C OHL04064 0.005 0.01 0.02 0.05 0.1 0.2 0.3 0 ...

Page 12

... Released 6) Seite 18 Maßzeichnung 6) page 18 Package Outlines Kathodenkennung: Cathode mark: Gewicht / Approx. weight: Gurtung / Polarität und Lage Method of Taping / Polarity and Orientation 2009-09-22 Markierung mark 7 Seite 18 Verpackungseinheit 4000/Rolle, ø180 mm 6) page 18 Packing unit 4000/reel, ø180 mm 12 LUW C9EP ...

Page 13

... As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. 2009-09-22 6) Seite 18 Reflow Löten 6) page 18 Reflow Soldering 0.35 (0.014) 3 (0.118) 0.6 (0.024) 1.2 (0.047 (0.118) OHLY2868 LUW C9EP ...

Page 14

... Vorbehandlung nach JEDEC Level 2 Preconditioning acc. to JEDEC Level 2 (nach J-STD-020B) (acc. to J-STD-020B) Maximum Solder Profile Recommended Solder Profile Minimum Solder Profile 120 s max 100 150 14 LUW C9EP OHLA0687 +0 ˚C 260 ˚C -5 ˚C 245 ˚C ±5 ˚C +5 ˚C 235 ˚C -0 ˚ min ...

Page 15

... Forward Voltage Group Wavelength Group Brightness Group OHA12043 Label Direction of unreeling Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: 160 mm Trailer: 160 1.5 + 0.1 1.75 ± 0.1 (0.059 + 0.004) (0.069 ± 0.004) LUW C9EP OHAY0324 F 3.5 ± 0.05 (0.138 ± 0.002 max 14.4 (0.567) ...

Page 16

... WET units bake 15% necessary if units, examine wet, If units bake 10% necessary if units, wet, examine If dry. adequately desiccant still change parts 5% wet, If MIL-I-8835 Indicator Humidity Desiccant Barcode label 16 Humidity indicator Barcode label OHA00539 Barcode label Packing Sealing label LUW C9EP OHA02044 ...

Page 17

... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 7) page 18 components may only be used in life-support devices or systems OSRAM OS. 2009-09-22 8) page 18 with the express written approval of 17 LUW C9EP Date of change 2007-12-03 2008-04-15 2008-04-15 2008-07-22 2008-05-01 2008-11-06 2009-05-29 2009-07-21 ...

Page 18

... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health and the life of the user may be endangered. 18 LUW C9EP figures. These do not If requested, e.g. because ...

Related keywords