LB M673-L1N2-35-0-10-R18-Z OSRAM Opto Semiconductors Inc, LB M673-L1N2-35-0-10-R18-Z Datasheet - Page 18

LED TOPLED 471NM BLUE CLR SMD

LB M673-L1N2-35-0-10-R18-Z

Manufacturer Part Number
LB M673-L1N2-35-0-10-R18-Z
Description
LED TOPLED 471NM BLUE CLR SMD
Manufacturer
OSRAM Opto Semiconductors Inc
Series
TOPLEDr

Specifications of LB M673-L1N2-35-0-10-R18-Z

Color
Blue
Luminous Flux @ Current - Test
88 mlm
Millicandela Rating
28.1mcd
Current - Test
10mA
Wavelength - Dominant
471nm
Wavelength - Peak
466nm
Voltage - Forward (vf) Typ
3.1V
Lens Type
Clear
Lens Style/size
Rectangle, 1.5mm x 1mm
Package / Case
0805 (2012 Metric)
Size / Dimension
2.00mm L x 1.40mm W
Height
1.30mm
Viewing Angle
120°
Mounting Type
Surface Mount
Resistance Tolerance
471nm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
475-1385-2
LB M673-L1N2-35-0-10-R18-Z
LB M673-L1N2-35-Z
Q65110A1953
Remarks:
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
2008-03-05
Brightness groups are tested at a current pulse duration of 25 ms and a tolerance of ± 11%.
Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of
technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual
parameters of each single product, which could differ from the typical data and calculated correlations or the typical
characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any
further notice.
Driving the LED in reverse direction is suitable for short term application.
R
Wavelengths are tested at a current pulse duration of 25 ms and a tolerance of ±1 nm.
Forward voltages are tested at a current pulse duration of 1 ms and a tolerance of ±0.05 V.
In the range where the line of the graph is broken, you must expect higher brightness differences between single
LEDs within one packing unit.
Dimensions are specified as follows: mm (inch)
Package able to withstand TTW-soldering heat
A critical component is a component used in a life-support device or system whose failure can reasonably be
expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that
device or system.
Life support devices or systems are intended
(a) to be implanted in the human body,
or
(b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the
life of the user may be endangered.
thJA
results from mounting on PC board FR 4 (pad size ≥ 5 mm
18
2
per pad)
LB M673, LT M673