LA E63F-EAFA-24-1-50-R33-Z OSRAM Opto Semiconductors Inc, LA E63F-EAFA-24-1-50-R33-Z Datasheet
LA E63F-EAFA-24-1-50-R33-Z
Specifications of LA E63F-EAFA-24-1-50-R33-Z
LA E63F-EAFA-24-1-50-R33-Z
LA E63F-EAFA-24-1-Z
Q65110A1845
Related parts for LA E63F-EAFA-24-1-50-R33-Z
LA E63F-EAFA-24-1-50-R33-Z Summary of contents
Page 1
... Power TOPLED with Lens Enhanced Thin Film LED Lead (Pb) Free Product - RoHS Compliant LS E63F, LA E63F, LY E63F Released This data sheet is under PCN-revision (see separate data sheet with respect to OS-PCN-2010-033-A). Not to be used for design-in. Besondere Merkmale • Gehäusetyp: weißes P-LCC-4 Gehäuse, farbloser klarer Verguss • ...
Page 2
... The above Type Numbers represent the order groups which include only a few brightness groups (see page 5 for explanation). Only one group will be shipped on each reel (there will be no mixing of two groups on each reel). E.g. LA E63F-EAFA-24-3B5A means that only one group EA will be shippable for any one reel. In order to ensure availability, single brightness groups will not be orderable. ...
Page 3
... Sperrspannung 3) page 16 Reverse voltage ( T =25°C) A Leistungsaufnahme Power consumption T ( =25°C) A Wärmewiderstand Thermal resistance 4) Seite 16 Sperrschicht/Umgebung 4) page 16 Junction/ambient Sperrschicht/Lötpad Junction/soldering point 2010-07-07 LS E63F, LA E63F, LY E63F Symbol Wert Symbol Value T – 40 … + 100 op T – 40 … + 100 stg T + 125 100 ...
Page 4
... V (min.) F (typ (max.) F (typ (max (typ.) λpeak (typ.) TC λdom TC (typ.) V η (typ.) opt 4 LS E63F, LA E63F, LY E63F Werte Einheit Values Unit 645 624 597 nm 633 617* 590* nm ± 6 –5/+7 –7/+ Grad deg. 1.90* 1.90* 2.05 ...
Page 5
... Seite 16 Luminous Intensity (mcd 5600 4200 (typ.) 7100 5300 (typ.) 9000 6700 (typ.) 8500 (typ.) 10600 (typ.) 13400 (typ.) 16900 (typ.) Wellenlänge Wavelength E63F, LA E63F, LY E63F yellow Einheit Unit max. nm 586 nm 589 nm 592 nm 595 nm yellow Einheit Unit min. max. 2.05 2 ...
Page 6
... Prinzipieller Messaufbau für Partial Flux Messung Schematic test method for partial flux measurement 2010-07-07 LS E63F, LA E63F, LY E63F Referenzebene des Detektors (ø14 mm) Reference layer of detector (ø14 mm) θ = 40˚ OHAY0907 6 ...
Page 7
... Seite 16 2) page 16 V λ yellow amber super-red 500 550 20˚ 10˚ 0˚ ϕ 1.0 0.8 0.6 0.4 0.2 0 0.4 0 20˚ E63F, LA E63F, LY E63F OHL22732 600 650 nm λ OHL00021 40˚ 60˚ 80˚ 100˚ 120˚ 700 ...
Page 8
... Relative Lichtstärke Relative Luminous Intensity V(50 mA) OHL02710 (50 mA) 2 Seite 15 Relative Lichtstärke Relative Luminous Intensity = V(25 °C) OHL02667 ˚C 100 E63F, LA E63F, LY E63F 2) 7) Seite page ° Seite 15 2) page 2.5 V (25 ˚C) 2.0 yellow 1 ...
Page 9
... 2010-07-07 OHL01413 ˚C 100 Zulässige Impulsbelastbarkeit F p Permissible Pulse Handling Capability = 25 °C Duty cycle OHL02046 0. 0.005 F 0.01 0.10 0.02 0.05 0.08 0.06 0.04 0. E63F, LA E63F, LY E63F parameter °C A OHL02045 D A 0.005 0.01 0.02 0.05 0.1 0.2 0 ...
Page 10
... S / 336h 336h 2 abgeschrägte Ecke bevelled edge 38 mg Verpackungseinheit 2000/Rolle, ø330 mm 8) page 16 Packing unit 2000/reel, ø330 mm 4 (0.157) 1.5 (0.059) 2.9 (0.114) 8 (0.315 E63F, LA E63F, LY E63F 0.9 (0.035) 0.7 (0.028 0.6 (0.024 0.4 (0.016) GPLY6113 3.65 (0.144) 2 (0.079) 1.5 (0.059 ...
Page 11
... TTW Soldering Anode 2.8 (0.110) 2.8 (0.110) Fläche darf elektrisch nicht beschaltet werden. Do not use this area for electrical contact E63F, LA E63F, LY E63F Fläche darf elektrisch nicht beschaltet werden. Do not use this area for electrical contact. 3.3 (0.130) Kathode/ Cathode < ...
Page 12
... Vorbehandlung nach JEDEC Level 2 Preconditioning acc. to JEDEC Level 2 (nach J-STD-020C) (acc. to J-STD-020C) OS-PCN-2010-033-A (nach CECC 00802) (acc. to CECC 00802 Welle 2. wave 5 K/s Zwangskühlung 2 K/s forced cooling 50 100 12 LS E63F, LA E63F, LY E63F Normalkurve standard curve Grenzkurven limit curves 2 K/s 150 200 t OHLY0598 s 250 ...
Page 13
... ± 0.1 2 ± 0.05 (0.315 ± 0.004) (0.079 ± 0.002 min 1 12 (0.488 + 0.079) 60 (2.362 E63F, LA E63F, LY E63F Bin1: Bin Information Color 1 Lx xxxx Bin2: Bin3: ML Temp ST 2 260 C RT Additional TEXT R077 DEMY PACKVAR: Packing Type (G) GROUP Forward Voltage Group ...
Page 14
... If desiccant change dry. adequately still parts 5% wet, If MIL-I-8835 Indicator Humidity Barcode label Packing Sealing label Länge / length ± ± 352 5 (13,858 0,1968 E63F, LA E63F, LY E63F Barcode label OHA00539 Barcode label OHA02044 Höhe / height ± ± (1,3 0,1968) ...
Page 15
... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 9) page 16 components may only be used in life-support devices or systems OSRAM OS 2010-07-07 LS E63F, LA E63F, LY E63F 10) page 16 with the express written approval of 15 Date of change 2005-11-02 2006-05-29 2008-09-04 ...
Page 16
... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health and the life of the user may be endangered E63F, LA E63F, LY E63F or the typical characteristic 2 per pad) line.If ...