SFH4510 OSRAM Opto Semiconductors Inc, SFH4510 Datasheet - Page 8

EMITTER IR 950NM 5MM SMD RADIAL

SFH4510

Manufacturer Part Number
SFH4510
Description
EMITTER IR 950NM 5MM SMD RADIAL
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of SFH4510

Current - Dc Forward (if)
100mA
Radiant Intensity (ie) Min @ If
2.5mW/sr @ 100mA
Wavelength
950nm
Voltage - Forward (vf) Typ
1.5V
Viewing Angle
28°
Orientation
Side View
Mounting Type
Through Hole
Package / Case
T 1 3/4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
475-1106-2
Q62702P1798

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SFH4510
Quantity:
56 815
Part Number:
SFH4510
Manufacturer:
OSRAM/欧司朗
Quantity:
20 000
Lötbedingungen
Soldering Conditions
Reflow Lötprofil für bleifreies Löten
Reflow Soldering Profile for lead free soldering
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2007-04-02
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
T
300
250
200
150
100
50
˚C
1
0
, may only be used in life-support devices or systems
0
255 ˚C
240 ˚C
217 ˚C
25 ˚C
Ramp Up
3 K/s (max)
50
120 s max
min. condition for IR Reflow Soldering:
solder point temperature ≥ 235 °C for at least 10 sec.
100
Recommended Solder Profile
Maximum Solder Profile
Minimum Solder Profile
8
150
Vorbehandlung nach JEDEC Level 3
Preconditioning acc. to JEDEC Level 3
(nach J-STD-020C)
(acc. to J-STD-020C)
2
with the express written approval of OSRAM OS.
200
100 s max
30 s max
SFH 4510, SFH 4515
Ramp Down
6 K/s (max)
10 s min
t
250
260 ˚C
245 ˚C
235 ˚C
OHLA0687
s
+0 ˚C
-5 ˚C
+5 ˚C
-0 ˚C
±5 ˚C
300

Related parts for SFH4510