SFH 415 U E9191 OSRAM Opto Semiconductors Inc, SFH 415 U E9191 Datasheet - Page 7

no-image

SFH 415 U E9191

Manufacturer Part Number
SFH 415 U E9191
Description
EMITTER IR 5MM 950NM
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of SFH 415 U E9191

Wavelength
950nm
Package / Case
Radial - 2 Lead
Current - Dc Forward (if)
100mA
Radiant Intensity (ie) Min @ If
40mW/sr @ 100mA
Voltage - Forward (vf) Typ
1.3V
Viewing Angle
34°
Orientation
Top View
Mounting Type
Through Hole
Radiant Intensity
600 mW/sr
Maximum Forward Current
100 mA
Maximum Power Dissipation
165 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Lens Shape
Circular
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q62702P1775
Lötbedingungen
Soldering Conditions
Wellenlöten (TTW)
TTW Soldering
Published by
OSRAM Opto Semiconductors GmbH
Leibnizstrasse 4, D-93055 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
1
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2009-08-21
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
T
300
250
200
150
100
50
C
0
0
1
, may only be used in life-support devices or systems
235 C
100
C
... 260
... 130
C
C
ca 200 K/s
1. Welle
1. wave
50
2 K/s
10 s
Zwangskühlung
forced cooling
5 K/s
100
2. Welle
2. wave
7
(nach CECC 00802)
(acc. to CECC 00802)
2
2 K/s
with the express written approval of OSRAM OS.
150
t
Normalkurve
standard curve
Grenzkurven
limit curves
200
SFH 415
s
OHLY0598