EXII-7710UC 3M, EXII-7710UC Datasheet - Page 11

CONTROLLER EX II USB CAPACITIVE

EXII-7710UC

Manufacturer Part Number
EXII-7710UC
Description
CONTROLLER EX II USB CAPACITIVE
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7710UC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC
Resolution
16 K x 16 K
For Use With/related Products
Touch Screen Capacitive
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5539
3M™ MicroTouch™ Controller EX USB Reference Guide
Sensor Connection
Mounting the Controller
The sensor cable has a 12-pin (2 x 6) dual row female connector that plugs into the
EX121 controller. Table 2 describes the pins on this connector. The sensor connector
always exits towards the USB cable.
Table 2. Sensor Cable Connector for EX121 Controllers
Pin
1
2
3
4
5
6
7
8
9
10
11
12
The sensor flex tail has a 5-pin single row female connector that plugs into the EX111
controller with a right side tail exit. The following table describes the pins on this
connector.
Table 3. Sensor Flex Tail Connector for EX111 Controllers
Pin
1
2
3
4
5
The cased controller is mounted externally. The uncased controller is mounted internally.
Choose a convenient spot away from high-voltage, high power cables and electronics.
Use 4-40 plastic screws to mount the cased controller to eliminate possible ESD input
path. Metal or plastic screws can be used on the 2x3 board if the green ground wire is
used. Metal screws are required on the 1x2 board if a separate ground wire is not used.
The controller should be mounted in line with the sensor flex tail exit point to minimize
flexing. Refer to Figure 1 for more details on controller mounting.
Wire Color
———
———
———
———
Gray
Green
Orange
Brown Cable
shield/drain
wire
White
Red
Black
Blue
Description
Upper left (UL) corner
Upper right (UR) corner
Connects to the flex tail shield, which must not be grounded because the
EX111 drives the flex tail shield with an AC waveform.
Lower right (LR) corner
Lower left (LL) corner
3M Touch Systems, Inc. Proprietary Information
Description
NOVRAM interface
NOVRAM interface
NOVRAM interface
+5 VDC
Not used
Chassis (earth) ground
Not used
Connects to the flex tail shield, which must not be grounded
because the EX121 drives the flex tail shield with an AC
waveform.
Upper right (UR) corner
Lower right (LR) corner
Upper left (UL) corner
Lower left (LL) corner