EXII-7720SC 3M, EXII-7720SC Datasheet - Page 30

CONTROLLER EX II SER CAPACITIVE

EXII-7720SC

Manufacturer Part Number
EXII-7720SC
Description
CONTROLLER EX II SER CAPACITIVE
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7720SC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC to 12 VDC
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 40 C
Connector Type
RS232
Rohs Compliant
Yes
For Use With/related Products
Touch Screen Capacitive
For Use With
3M5754 - TOUCH SCREEN CAPACITIVE 12.31"3M5752 - TOUCH SCREEN CAPACITIVE 19.75"3M5750 - TOUCH SCREEN CAPACITIVE 20.65"3M5748 - TOUCH SCREEN CAPACITIVE 17.54"3M5747 - TOUCH SCREEN CAPACITIVE 6.71"3M5745 - TOUCH SCREEN CAPACITIVE 15.68"3M5744 - TOUCH SCREEN CAPACITIVE 10.83"3M5527 - TOUCH SCREEN CAPACITIVE 31.80"3M5526 - TOUCH SCREEN CAPACITIVE 20.65"3M5525 - TOUCH SCREEN CAPACITIVE 19.75"3M5524 - TOUCH SCREEN CAPACITIVE 17.54"3M5523 - TOUCH SCREEN CAPACITIVE 15.68"3M5522 - TOUCH SCREEN CAPACITIVE 12.31"3M5521 - TOUCH SCREEN CAPACITIVE 10.83"3M5520 - TOUCH SCREEN CAPACITIVE 8.75"3M5519 - TOUCH SCREEN CAPACITIVE 6.71"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5540

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EXII-7720SC
Manufacturer:
3M Touch Systems
Quantity:
135
30
Response:
Reset
Syntax:
Description:
Response:
Restore Defaults
Syntax:
Description:
<SOH>PN81<CR>
Caution: The settings are immediately written to NOVRAM, and all future
communication must occur at the new values. It is possible to set the parameters to values
that prevent future communication with the controller.
<SOH>0<CR>
<SOH>R<CR>
Initializes the hardware and the firmware, causes the controller to stop sending data, and
recalculates the environmental conditions (for example, stray and offset values). The
Reset command also cancels the Format Raw, Calibrate Raw, and Calibrate Extended
commands and returns the controller to normal operation.
3M Touch Systems recommends that the host system issue a Reset command whenever
the host system is powered on and is attempting to establish communication with the
controller.
The amount of time needed to execute a Reset command ranges from 225 milliseconds to
800 milliseconds. Therefore, the application program should wait and be sure it receives
the command response before issuing another command to the controller following the
reset.
<SOH>0<CR>
<SOH>RD<CR>
Returns to the factory default operating parameters. The Restore Defaults command
copies the 3M Touch Systems factory default parameters from ROM to the non-volatile
memory (NOVRAM) and then executes a Reset command.
Table 12 lists the factory defaults for the EX serial controller. The Restore Defaults
command is useful in situations where inadvertent commands to the controller have
rendered the sensor inoperative.
3M Touch Systems, Inc. Proprietary Information
Sets the parity, data bits, and stop bits; leaves the baud at its
previous value.
Positive response.
Positive response.
3M™ MicroTouch™ Controller EX Serial Reference Guide

Related parts for EXII-7720SC