EXII-7720SC 3M, EXII-7720SC Datasheet - Page 18

CONTROLLER EX II SER CAPACITIVE

EXII-7720SC

Manufacturer Part Number
EXII-7720SC
Description
CONTROLLER EX II SER CAPACITIVE
Manufacturer
3M
Series
MicroTouch™ Controller EXr
Datasheets

Specifications of EXII-7720SC

Accessory Type
Touch Screen - Controller
Operating Supply Voltage
5 VDC to 12 VDC
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 40 C
Connector Type
RS232
Rohs Compliant
Yes
For Use With/related Products
Touch Screen Capacitive
For Use With
3M5754 - TOUCH SCREEN CAPACITIVE 12.31"3M5752 - TOUCH SCREEN CAPACITIVE 19.75"3M5750 - TOUCH SCREEN CAPACITIVE 20.65"3M5748 - TOUCH SCREEN CAPACITIVE 17.54"3M5747 - TOUCH SCREEN CAPACITIVE 6.71"3M5745 - TOUCH SCREEN CAPACITIVE 15.68"3M5744 - TOUCH SCREEN CAPACITIVE 10.83"3M5527 - TOUCH SCREEN CAPACITIVE 31.80"3M5526 - TOUCH SCREEN CAPACITIVE 20.65"3M5525 - TOUCH SCREEN CAPACITIVE 19.75"3M5524 - TOUCH SCREEN CAPACITIVE 17.54"3M5523 - TOUCH SCREEN CAPACITIVE 15.68"3M5522 - TOUCH SCREEN CAPACITIVE 12.31"3M5521 - TOUCH SCREEN CAPACITIVE 10.83"3M5520 - TOUCH SCREEN CAPACITIVE 8.75"3M5519 - TOUCH SCREEN CAPACITIVE 6.71"
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3M5540

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EXII-7720SC
Manufacturer:
3M Touch Systems
Quantity:
135
18
Controller Default Settings
Communicating with the Controller
Communication Parameters
The default operation of the EX serial controllers is N81 (no parity, 8 data bits, and 1 stop
bits) at 9600 baud. Some EX122 controllers can be programmed to work with even/odd
parity, 7 data bits, and 1 or 2 stop bits.
Data Format
Data format refers to the type of packet the controller uses to send the X/Y touch
coordinates to the host system. Format Tablet is the default format for the 3M™
MicroTouch™ EX serial controller. In Format Tablet, the controller sends 5 bytes per
point and provides the most rapid response time to a touch.
Refer to the Format Tablet command in the firmware reference section. Note that 3M
MicroTouch Software automatically sets communications parameters to N81.
Operating Mode
The operating mode specifies the conditions under which the controller sends the X/Y
touch coordinates (input data packet) to the host system.
Mode Stream is the default operating mode for the EX serial controller. In Mode Stream,
the controller sends a continuous stream of data packets when the sensor is touched. The
controller sends the data as long as a touch continues on the sensor.
Because Mode Stream sends touch data continually, it is the most versatile mode, and it
provides the best response time and overall feel.
3M Touch Systems recommends that the touch driver generate an interrupt as each packet
in the data stream arrives. Because touchdown and liftoff events are specially coded, your
software can generate mouse events that correspond to what the user is doing. This
enables instant feedback and prevents data loss.
This section provides information on sending firmware commands to the controller and
interpreting the responses that the controller returns.
The commands listed in the following table are those that 3M Touch Systems currently
uses for development. 3M Touch Systems recommends that you use only these
commands for 3M™ MicroTouch™ EX serial controller development.
Format Tablet is supported by all current 3M™ MicroTouch™ touch controllers.
It is the standard for current 3M Touch Systems product development and is the
format used by all touch drivers written by 3M Touch Systems.
3M Touch Systems, Inc. Proprietary Information
3M™ MicroTouch™ Controller EX Serial Reference Guide

Related parts for EXII-7720SC