SE-K2EN Omron, SE-K2EN Datasheet - Page 2

no-image

SE-K2EN

Manufacturer Part Number
SE-K2EN
Description
RELAY MOTOR PROTECT 200/220/240V
Manufacturer
Omron
Series
SEr
Datasheet

Specifications of SE-K2EN

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SEK2EN
SE-@@N
Overcurrent operating value: 115% of current SV.
Note: 1. With start-up lock: fixed time-limit on start-up, instantaneous thereafter.
■ Accessories (Order Separately)
Current Converters
Specifications
■ Ratings
Output Contact Capacity
100/110 120 VAC
200/220/240 VAC
100/110/120 VAC
200/220/240 VAC
380/400/440 VAC
SET-3A
SET-3B
8PFA1
Motor circuit
Power supply circuit
Current SV range
Output relay contact
Power consumption
Case color
100/110/120 VAC or
200/220/240 VAC
380/400/440 VAC
Control voltage
DIN rail socket
Control power supply
2. The operating value for the overload detection function of the SE-@@N is 115% of the current SV.
Model
1 to 80 A
64 to 160 A
Manual
Automatic
Manual
Automatic
Manual
Automatic
Manual
Automatic
Manual
Automatic
Current range
Reset
NO
NC
NO
NC
Voltage: 500 VAC max. 3-phase (primary voltage at SET current converter)
Current: 1 to 80 A or 64 to 160 A 3-phase (primary current at SET current converter)
Voltage: 100/110/120 VAC, 200/220/240 VAC, or 380/400/440 VAC 3-phase
(treat as a single phase voltage when the reverse-phase function is not needed)
Voltage fluctuation: +10/−15% max. of the rated voltage (+10/−50% max. for open-phase function)
Frequency: 50/60 Hz ±5%
See table of Current Converter.
Configuration: SPDT
Capacity:
100/110/120 VAC: approx. 3.5 VA; 200/220/240 VAC: approx. 7 VA; 380/400/440 VAC: approx. 11 VA
Plug-in model: Munsell 5Y7/1
Panel-mount model: Munsell N1.5
Contact
3 A (cosφ = 1.0)/1.5 A (cosφ = 0.3 to 0.4) at 240 VAC 3 A (cosφ = 1.0)/2 A (cosφ = 0.4) at 240 VAC
3 A (cosφ = 1.0)/2 A (cosφ = 0.3 to 0.4) at 240 VAC
3 A (cosφ = 1.0)/1.5 A (cosφ = 0.3 to 0.4) at 440 VAC ---
3 A (cosφ = 1.0)/2 A (cosφ = 0.3 to 0.4) at 440 VAC
SE-KP1N
SE-KP1AN
SE-KP2N
SE-KP2AN
SE-K1N
SE-K1AN
SE-K2N
SE-K2AN
SE-K4N
---
Refer to the table below.
Inverse type
Manual reset
3-phase Transformer
Specify the primary voltage when ordering.
Only one SE relay can be connected.
Adapter
This Adapter is used to replace existing flush mount models with new
models.
SE-PT400
SE-F7AD
Model
Model
Instantaneous type (See note 1.)
SE-KQP1N
SE-KQP1AN
SE-KQP2N
SE-KQP2AN
SE-KQ1N
SE-KQ1AN
SE-KQ2N
SE-KQ2AN
SE-KQ4N
---
Model
Primary side
Secondary side 190 to 240 V
Voltage specification
380 to 480 V
(wide power
supply range)
(wide power
supply range)
Automatic reset
Secondary power
7 VA
consumption
SE
2