DS1923-F5# Maxim Integrated Products, DS1923-F5# Datasheet - Page 45

IBUTTON TEMP/HUMIDITY LOGGER F5

DS1923-F5#

Manufacturer Part Number
DS1923-F5#
Description
IBUTTON TEMP/HUMIDITY LOGGER F5
Manufacturer
Maxim Integrated Products
Series
iButton®r
Datasheet

Specifications of DS1923-F5#

Rohs Information
IButton RoHS Compliance Plan
Memory Size
512B
Memory Type
NVSRAM (Non-Volatile SRAM)
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
DS1923-F5#
Manufacturer:
Maxim
Quantity:
2
Company:
Part Number:
DS1923-F5#
Manufacturer:
MAXIM/美信
Quantity:
20 000
ing in the command code, the target addresses TA1
and TA2, and all the data bytes. The DS1923 transmits
this CRC only if the data bytes written to the scratchpad
include scratchpad ending offset 11111b. The data can
start at any location within the scratchpad.
With the Read Scratchpad command, the CRC is gen-
erated by first clearing the CRC generator and then
<Data to EOM>
<Data to EOS>
<Data to EOP>
<PW/Dummy>
<32 Bytes>
SYMBOL
AA Loop
FF Loop
<Data>
CRC-16
TA–E/S
Select
RMC
RST
CPS
STP
FFh
CM
WS
SM
PD
RS
FC
TA
Hygrochron Temperature/Humidity Logger
______________________________________________________________________________________
Command-Specific 1-Wire Communication Protocol—Legend
1-Wire reset pulse generated by master.
1-Wire presence pulse generated by slave.
Command and data to satisfy the ROM function protocol.
Command “Write Scratchpad.”
Command “Read Scratchpad.”
Command “Copy Scratchpad with Password.”
Command “Read Memory with Password and CRC.”
Command “Clear Memory with Password.”
Command “Forced Conversion.”
Command “Start Mission with Password.”
Command “Stop Mission with Password.”
Target Address TA1, TA2.
Target Address TA1, TA2 with E/S byte.
Transfer of as many data bytes as are needed to reach the scratchpad offset 1Fh.
Transfer of as many data bytes as are needed to reach the end of a memory page.
Transfer as many bytes as are needed to reach the end of the data-log memory.
Transfer of 8 bytes that either represent a valid password or acceptable dummy data.
Transfer of 32 bytes.
Transfer of an undetermined amount of data.
Transmission of one FFh byte.
Transfer of an inverted CRC-16.
Indefinite loop where the master reads FF bytes.
Indefinite loop where the master reads AA bytes.
iButton with 8KB Data-Log Memory
shifting in the command code, the target addresses
TA1 and TA2, the E/S byte, and the scratchpad data
starting at the target address. The DS1923 transmits
this CRC only if the reading continues through the end
of the scratchpad, regardless of the actual ending off-
set. For more information on generating CRC values,
refer to Application Note 27.
DESCRIPTION
45

Related parts for DS1923-F5#