HCPL-3700-000E Avago Technologies US Inc., HCPL-3700-000E Datasheet
HCPL-3700-000E
Specifications of HCPL-3700-000E
Available stocks
Related parts for HCPL-3700-000E
HCPL-3700-000E Summary of contents
Page 1
... The HCPL-0370/3700 and HCPL-3760 are voltage/ current threshold detection optocouplers. The HCPL- 3760 is a low-current version of the HCPL-0370/ 3700. To obtain lower current operation, the HCPL- 3760 uses a high-efficiency AlGaAs LED which provides higher light output at lower drive currents. The devices utilize threshold sensing input buffer ICs which permit control of threshold levels over a wide range of input voltages with a single external resistor ...
Page 2
... The nominal turn on threshold for the HCPL-3760 is 1 and 3.7 volts (V +). TH TH Ordering Information HCPL-0370/HCPL-3700/HCPL-3760 is UL Recognized with 3750 Vrms for 1 minute per UL1577 unless otherwise specified. Option Part RoHS non RoHS Number Compliant Compliant HCPL-0370 ...
Page 3
... A XXXX YYWW PIN ONE 1.19 (0.047) MAX. 3.56 ± 0.13 (0.140 ± 0.005) 0.76 (0.030) 1.40 (0.056) Gull Wing Surface Mount Option 300 (HCPL-3700/3760) 9.65 ± 0.25 (0.380 ± 0.010 TYPE NUMBER DATE CODE A XXXX R YYWW MOLDED 1.19 (0.047) MAX. 1.080 ± ...
Page 4
... Package Outline Drawings, continued Small Outline SO-8 Package (HCPL-0370 XXX 3.937 ± 0.127 YWW (0.155 ± 0.005 PIN ONE 0.406 ± 0.076 (0.016 ± 0.003) * 5.080 ± 0.127 (0.200 ± 0.005) 3.175 ± 0.127 (0.125 ± 0.005) * TOTAL PACKAGE LENGTH (INCLUSIVE OF MOLD FLASH) 5.207 ± ...
Page 5
... Note: Non-halide flux should be used. Regulatory Information The HCPL-0370/3700/3760 has been approved by the following organizations: UL Recognized under UL 1577, component recognition program, File E55361 (HCPL-0370 pending). CSA Approved under CSA Component Acceptance Notice #5, File CA 88324. 5 PEAK PEAK TEMP. TEMP. ...
Page 6
... DIN IEC 112/VDE 0303 PART 1 IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Symbol Temperature Time Average Surge I IN Transient V IN HCPL-3700/3760 P IN HCPL-0370 HCPL-3700/3760 P T HCPL-0370 HCPL-3700/3760 P O HCPL-0370 Average See Package Outline Drawings section Symbol Min Min. Max. Units ...
Page 7
... Input Clamp Voltage V IHC1 V IHC2 V IHC3 V ILC Input Current I HCPL-0370/3700 IN HCPL-3760 Bridge Diode V HCPL-0370/3700 D1,2 Forward Voltage HCPL-3760 V HCPL-0370/3700 D3,4 HCPL-3760 Logic Low Output V OL Voltage Logic High I OH Output Current Logic Low Supply I HCPL-0370/3700 CCL Current HCPL-3760 Logic High Supply ...
Page 8
... Time to Logic Low t PHL at Output HCPL-3760 Propagation Delay HCPL-0370/3700 Time to Logic High t PLH at Output HCPL-3760 HCPL-0370/3700 Output Rise Time t r (10-90%) HCPL-3760 HCPL-0370/3700 Output Fall Time t f (90-10%) HCPL-3760 Common Mode Transient Immunity | Logic High Output Common Mode HCPL-0370/3700 Transient Immunity | ...
Page 9
... Surge input current duration 120 Hz pulse repetition rate. Transient input current duration 120 Hz pulse repetition rate. Note that maximum input power must be observed Derate linearly above 70 C free-air temperature at a rate of 4.1 mW/ C (HCPL-3700/3760) and 3.1 mW/ C (HCPL-0370). Maximum input power dissipation of 230 mW (HCPL-3700/3760) and 172 mW (HCPL-0370) allows an input IC junction temperature of 125 ambient temperature Excessive P and T may result in IC chip degradation ...
Page 10
... I 3.4 1.2 TH+ 3.2 1.1 3.0 1.0 V TH- 2.8 0.9 2.6 0.8 2.4 0.7 I TH- 2.2 0.6 2.0 0.5 1.8 0.4 -40 - – TEMPERATURE – °C A HCPL-3760 2.1 2.0 1 1.6 (PINS 5.0 V 1.5 CC 1 4.2 mA 1.2 OL 1.1 1.0 0.9 -40 - – TEMPERATURE – ° ...
Page 11
... Figure 9. Common mode transient immunity vs. common mode transient amplitude. 11 HCPL-3760 PULSE WIDTH 100 µs (10-90 PLH PHL 2 0 -40 - – TEMPERATURE – °C A HCPL-3760 30 700 25 600 20 500 15 400 4 5 300 CC 5 PULSE WIDTH 100 Hz 5 200 µs (10-90 100 -40 - – TEMPERATURE – °C A ...
Page 12
... HCPL-0370/3700/3760 Figure 10. Switching test circuit. HCPL-0370/3700/3760 Figure 11. Test circuit for common mode transient immunity and typical waveforms. HCPL-0370/3700 V = 3 2.6 V TH– 4 3.7 V TH– 2 1.3 mA TH– °C A Figure 12. Typical external threshold characteristics vs (0370/3700) ...
Page 13
... Equations (2) and (3). R can provide over-current X transient protection by limiting input current during a transient condition. For monitoring con- tacts of a relay or switch, the HCPL-0370/3700/3760 in combination with R and R can used to allow a specific current to be conducted through the contacts for cleaning purposes (wetting current). ...
Page 14
For product information and a complete list of distributors, please go to our website: Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies Limited in the United States and other countries. Data subject to change. Copyright © ...