HCPL-3700 Avago Technologies US Inc., HCPL-3700 Datasheet
HCPL-3700
Specifications of HCPL-3700
Available stocks
Related parts for HCPL-3700
HCPL-3700 Summary of contents
Page 1
... LOGIC) INPUT OUTPUT HCPL-3700 Functional Diagram CAUTION advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation which may be induced by ESD. Features • Standard (HCPL-0370/3700) and low input current (HCPL-3760) versions • input • Programmable sense voltage • ...
Page 2
... Example 1: HCPL-3760-500E to order product of Gull Wing Surface Mount package in Tape and Reel packaging with and RoHS compliant. Example 2: HCPL-3700 to order product of 300 mil DIP package in Tube packaging and non RoHS compliant. Option datasheets are available. Contact your Avago sales representative or authorized distributor for information. ...
Page 3
... Schematic Package Outline Drawings Standard DIP Package (HCPL-3700/3760) 9.40 (0.370) 9.90 (0.390 XXXX YYWW PIN ONE 1.19 (0.047) MAX. 3.56 ± 0.13 (0.140 ± 0.005) 0.76 (0.030) 1.40 (0.056 TYPE NUMBER DATE CODE 6.10 (0.240) 6.60 (0.260) 7.36 (0.290) 7.88 (0.310) ...
Page 4
... Package Outline Drawings, continued Gull Wing Surface Mount Option 300 (HCPL-3700/3760) 9.65 ± 0.25 (0.380 ± 0.010 TYPE NUMBER DATE CODE A XXXX R U YYWW MOLDED 1.19 (0.047) MAX. 1.080 ± 0.320 (0.043 ± 0.013) 2.540 (0.100) BSC DIMENSIONS IN MILLIMETERS (INCHES). TOLERANCES (UNLESS OTHERWISE SPECIFIED): LEAD COPLANARITY MAXIMUM: 0 ...
Page 5
... T = 150 °C smax smin Note: Non-halide flux should be used. Regulatory Information The HCPL-0370/3700/3760 has been approved by the following organizations: IEC/EN/DIN EN 60747-5-5 (with option 060) Maximum Working Insulation Voltage V for HCPL-0370, and 630 Vpeak for HCPL3700/3760. Highest Allowable Overvoltage V IOTM HCPL-0370/3700/3760 ...
Page 6
... Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the application. 2. Safety-limiting parameters are dependent on case temperature. The Input Current rate of 1.2 mA/°C and 1.53 mA/°C for HCPL-0370 and HCPL-3700/3760 respectively; the Output Power, P free-air case temperature at a rate of 4.8 mW/°C and 4 mW/°C for HCPL-0370 and HCPL-3700/3760 respectively. 6 ...
Page 7
... Solder Reflow Temperature Profile Recommended Operating Conditions Parameter Supply Voltage Operating Temperature Operating Frequency 7 Symbol Temperature Time Average Surge I IN Transient V IN HCPL-3700/3760 P IN HCPL-0370 HCPL-3700/3760 P T HCPL-0370 HCPL-3700/3760 P O HCPL-0370 Average See Package Outline Drawings section Symbol Min. Max Min. Max. Units ...
Page 8
... HYS Input Clamp V IHC1 Voltage V IHC2 V IHC3 V ILC Input Current I HCPL-0370/3700 IN HCPL-3760 Bridge Diode V HCPL-0370/3700 D1,2 Forward Voltage HCPL-3760 V HCPL-0370/3700 D3,4 HCPL-3760 Logic Low V OL Output Voltage Logic High I OH Output Current Logic Low I HCPL-0370/3700 CCL Supply Current HCPL-3760 Logic High I ...
Page 9
... Time to Logic Low t PHL at Output HCPL-3760 Propagation Delay HCPL-0370/3700 Time to Logic High t PLH at Output HCPL-3760 HCPL-0370/3700 Output Rise Time t r (10-90%) HCPL-3760 HCPL-0370/3700 Output Fall Time t f (90-10%) HCPL-3760 Common Mode Transient Immunity | Logic High Output Common Mode HCPL-0370/3700 Transient Immunity | ...
Page 10
... Note that maximum input power must be observed Derate linearly above 70°C free-air temperature at a rate of 4.1 mW/°C (HCPL-3700/3760) and 3.1 mW/°C (HCPL-0370). Maximum input power dissipation of 230 mW (HCPL-3700/3760) and 172 mW (HCPL-0370) allows an input IC junction temperature of 125° ambient tempera- ture 70°C. Excessive P and T may result in IC chip degradation ...
Page 11
... SUPPLY VOLTAGE – HCPL-370 fig 1.6 1 CCH OPEN 1 1.1 1.0 -3 0.9 10 0.8 0 0.6 0.5 0 -40 - – TEMPERATURE – °C A Figure 4. Typical high level supply current, I HCPL-3700 fig 4 temperature. 240 220 200 180 160 140 120 100 18.0 20.0 I CCH vs. CCH ...
Page 12
... HCPL-3760 4.7 kΩ 5 5 PULSE WIDTH 100 µs (10-90 PLH PHL 2 0 -40 - – TEMPERATURE – °C A HCPL-3700 fig 7b HCPL-3760 30 700 25 600 20 500 15 400 4.7 kΩ 5 300 CC 5 PULSE WIDTH 100 Hz 5 200 µs (10-90 100 -40 - – TEMPERATURE – °C A HCPL-3700 fig 8b ...
Page 13
Figure 10. Switching test circuit. Figure 11. Test circuit for common mode transient immunity and typical waveforms. Figure 12. Typical external threshold characteristics, V ± vs ...
Page 14
... R can provide over-current transient protection by X limiting input current during a transient condition. For monitoring con tacts of a relay or switch, the HCPL- 0370/3700/3760 in combina tion with R used to allow a specific current to be conducted through the contacts for clean ing purposes (wetting current). The choice of which input voltage clamp level to choose depends upon the application of this device (see Figure 1) ...