SI8410-A-IS Silicon Laboratories Inc, SI8410-A-IS Datasheet - Page 20

no-image

SI8410-A-IS

Manufacturer Part Number
SI8410-A-IS
Description
IC ISOLATOR 1CH 2.5KV 1M 8SOIC
Manufacturer
Silicon Laboratories Inc
Series
ISOpror
Datasheet

Specifications of SI8410-A-IS

Inputs - Side 1/side 2
1/0
Number Of Channels
1
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
1Mbps
Propagation Delay
35ns
Output Type
Logic
Package / Case
8-SOIC (3.9mm Width)
Operating Temperature
-40°C ~ 125°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Isolation Rating
-
Other names
336-1354
SI8410-A-IS

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI8410-A-IS
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si8410/20/21
4. Layout Recommendations
Dielectric isolation is a set of specifications produced by safety regulatory agencies from around the world, which
describes the physical construction of electrical equipment that derives power from high-voltage power systems,
such as 100–240 V
specifications places a very high voltage between the input power pins of a product and the user circuits and the
user-touchable surfaces of the product. For the IEC relating to products deriving their power from the 220–240 V
power grids, the test voltage is 2500 V
There are two terms described in the safety specifications:
Figure 13 illustrates the accepted method of providing the proper creepage distance along the surface. For a
220–240 V application, this distance is 8 mm, and the wide-body SOIC package must be used. There must be no
copper traces within this 8 mm exclusion area, and the surface should have a conformal coating, such as solder
resist. The digital isolator chip must straddle this exclusion area.
4.1. Supply Bypass
The Si841x and Si842x families require a 0.1 µF bypass capacitor between V
The capacitor should be placed as close as possible to the package.
20
Creepage—the distance along the insulating surface an arc may travel.
Clearance—the shortest distance through air that an arc may travel.
AC
systems or industrial power. The dielectric test (or HIPOT test) given in the safety
AC
Figure 13. Creepage Distance
(or 3750 V
Preliminary Rev. 0.12
DC
, the peak equivalent voltage).
DD1
and GND1 and V
DD2
and GND2.

Related parts for SI8410-A-IS