ADT7460ARQZ ON Semiconductor, ADT7460ARQZ Datasheet - Page 34

no-image

ADT7460ARQZ

Manufacturer Part Number
ADT7460ARQZ
Description
IC REMOTE THRML/FAN CTRLR 16QSOP
Manufacturer
ON Semiconductor
Series
dBCool®r
Datasheets

Specifications of ADT7460ARQZ

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 120°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 120°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (3-Wire)
Maximum Operating Temperature
+ 120 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7460ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7460ARQZ-REEL
Manufacturer:
ST
Quantity:
16
1. This register becomes read−only when the Configuration Register 1 lock bit is set to 1. Further attempts to write to this register have no effect.
Table 45. Register 0x37 — Dynamic T
Bit No.
<2:0>
<5:3>
<7:6>
Mnemonic
CYR1
CYR2
CYL
R/W
R/W
R/W
R/W
3−Bit Remote 1 Cycle Value. These three bits define the delay time between making subsequent
T
cycles. The system has associated thermal time constants that need to be found to optimize the
response of fans and the control loop.
3−Bit Local Temperature Cycle Value. These three bits define the delay time between making
subsequent T
number of monitoring cycles. The system has associated thermal time constants that need to
be found to optimize the response of fans and the control loop.
2 LSBs of 3−Bit Remote 2 Cycle Value. The MSB of the 3−bit code resides in Dynamic T
Control Register 1 (Reg. 0x36). These three bits define the delay time between making
subsequent T
of monitoring cycles. The system has associated thermal time constants that need to be found
to optimize the response of fans and the control loop.
MIN
Bits
Bits
Bits
000
001
010
011
100
101
110
000
001
010
011
100
101
110
000
001
010
011
100
101
110
111
111
111
MIN
adjustments in the control loop for the Remote 1 channel, in terms of number of monitoring
Control Register 2 (Power−On Default = 0x00)
4 Cycles (0.5 s)
8 Cycles (1 s)
16 Cycles (2 s)
32 Cycles (4 s)
64 Cycles (8 s)
128 Cycles (16 s)
256 Cycles (32 s)
512 Cycles (64 s)
4 Cycles (0.5 s)
8 Cycles (1 s)
16 Cycles (2 s)
32 Cycles (4 s)
64 Cycles (8 s)
128 Cycles (16 s)
256 Cycles (32 s)
512 Cycles (64 s)
4 Cycles (0.5 s)
8 Cycles (1 s)
16 Cycles (2 s)
32 Cycles (4 s)
64 Cycles (8 s)
128 Cycles (16 s)
256 Cycles (32 s)
512 Cycles (64 s)
MIN
MIN
http://onsemi.com
adjustments in the control loop for local temperature channel, in terms of
adjustments in the control loop for the Remote 2 channel, in terms of number
ADT7460
Decrease Cycle
Decrease Cycle
Decrease Cycle
34
Description
8 Cycles (1 s)
16 Cycles (2 s)
32 Cycles (4 s)
64 Cycles (8 s)
128 Cycles (16 s)
256 Cycles (32 s)
512 Cycles (64 s)
1024 Cycles (128 s)
8 Cycles (1 s)
16 Cycles (2 s)
32 Cycles (4 s)
64 Cycles (8 s)
128 Cycles (16 s)
256 Cycles (32 s)
512 Cycles (64 s)
1024 Cycles (128 s)
8 Cycles (1 s)
16 Cycles (2 s)
32 Cycles (4 s)
64 Cycles (8 s)
128 Cycles (16 s)
256 Cycles (32 s)
512 Cycles (64 s)
1024 Cycles (128 s)
(Note 1)
Increase Cycle
Increase Cycle
Increase Cycle
MIN

Related parts for ADT7460ARQZ