MAX6602UE9A+T Maxim Integrated Products, MAX6602UE9A+T Datasheet - Page 13

IC TEMP MONITOR 5CH 16-TSSOP

MAX6602UE9A+T

Manufacturer Part Number
MAX6602UE9A+T
Description
IC TEMP MONITOR 5CH 16-TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6602UE9A+T

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Full Temp Accuracy
+/- 1 C, +/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 7. Status 1 Register
Table 8. Status 2 Register
7 (MSB)
7 (MSB)
BIT
BIT
6
5
4
3
2
1
0
6
5
4
3
2
1
0
Five-Channel Precision Temperature Monitor
Remote 4 ALERT
Remote 3 ALERT
Remote 2 ALERT
Remote 1 ALERT
Remote 4 OVERT
Remote 1 OVERT
Local ALERT
______________________________________________________________________________________
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
NAME
NAME
STATE
STATE
POR
POR
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Local Channel High-Alert Bit. This bit is set to logic 1 when the local
temperature exceeds the temperature threshold limit in the local ALERT high-
limit register.
Channel 4 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 4 remote-diode temperature exceeds the temperature threshold limit
in the remote 4 ALERT high-limit register.
Channel 3 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 3 remote-diode temperature exceeds the programmed temperature
threshold limit in the remote 3 ALERT high-limit register.
Channel 2 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 2 remote-diode temperature exceeds the temperature threshold limit
in the remote 2 ALERT high-limit register.
Channel 1 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the
channel 1 remote-diode temperature exceeds the temperature threshold limit
in the remote 1 ALERT high-limit register.
Channel 4 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 4 remote-diode temperature exceeds the temperature
threshold limit in the remote 4 OVERT high-limit register.
Channel 1 Remote-Diode Overtemperature Status Bit. This bit is set to logic 1
when the channel 1 remote-diode temperature exceeds the temperature
threshold limit in the remote 1 OVERT high-limit register.
FUNCTION