MAX6602UE9A+T Maxim Integrated Products, MAX6602UE9A+T Datasheet - Page 11

IC TEMP MONITOR 5CH 16-TSSOP

MAX6602UE9A+T

Manufacturer Part Number
MAX6602UE9A+T
Description
IC TEMP MONITOR 5CH 16-TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6602UE9A+T

Function
Temp Monitoring System (Sensor)
Topology
ADC, Buffer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-TSSOP
Full Temp Accuracy
+/- 1 C, +/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
In both cases, the alert is cleared even if the fault condi-
tion exists, but the ALERT output reasserts at the end of
the next conversion. The bits indicating the fault for the
OVERT interrupt output clear only on reading the status 2
register even if the fault conditions still exist. Reading the
Table 3. Command Byte Register Bit Assignment
Local
Remote 1
Remote 2
Remote 3
Remote 4
Configuration 1
Configuration 2
Configuration 3
Status1
Status2
Status3
Local ALERT High Limit
Remote 1 ALERT High Limit
Remote 2 ALERT High Limit
Remote 3 ALERT High Limit
Remote 4 ALERT High Limit
Remote 1 OVERT High Limit
Remote 4 OVERT High Limit
Remote 1 Extended
Temperature
Manufacturer ID
REGISTER
Five-Channel Precision Temperature Monitor
______________________________________________________________________________________
ADDRESS
(hex)
0A
07
01
02
03
04
41
42
43
44
45
46
17
11
12
13
14
21
24
09
POR STATE
(hex)
4D
00
00
00
00
00
00
00
00
00
00
00
5A
6E
7F
64
64
6E
7F
00
READ/
WRITE
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R
R
Read local temperature register
Read channel 1 remote temperature register
Read channel 2 remote temperature register
Read channel 3 remote temperature register
Read channel 4 remote temperature register
Read/write configuration register 1
Read/write configuration register 2
Read/write configuration register 3
Read status register 1
Read status register 2
Read status register 3
Read/write local alert high-temperature threshold limit register
Read/write channel 1 remote-diode alert high-temperature
threshold limit register
Read/write channel 2 remote-diode alert high-temperature
threshold limit register
Read/write channel 3 remote-diode alert high-temperature
threshold limit register
Read/write channel 4 remote-diode alert high-temperature
threshold limit register
Read/write channel 1 remote-diode overtemperature threshold
limit register
Read/write channel 4 remote-diode overtemperature threshold
limit register
Read channel 1 remote-diode extended temperature register
Read manufacturer ID
status 2 register does not clear the OVERT interrupt out-
put. To eliminate the fault condition, either the measured
temperature must drop below the temperature threshold
minus the hysteresis value (4°C), or the trip temperature
must be set at least 4°C above the current temperature.
DESCRIPTION
11