LM86CIM/NOPB National Semiconductor, LM86CIM/NOPB Datasheet - Page 14

IC TEMP SENSOR DGTL 8-SOIC

LM86CIM/NOPB

Manufacturer Part Number
LM86CIM/NOPB
Description
IC TEMP SENSOR DGTL 8-SOIC
Manufacturer
National Semiconductor
Datasheets

Specifications of LM86CIM/NOPB

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Supply Current
800µA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
SOIC
No. Of Pins
8
Filter Terminals
SMD
Rohs Compliant
Yes
Accuracy %
1°C
For Use With
LM86EVAL/NOPB - BOARD EVALUATION LM86
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.national.com
2.0 LM86 REGISTERS
2.2 LOCAL and REMOTE TEMPERATURE REGISTERS (LT, RTHB, RTLB)
For LT and RTHB D7–D0: Temperature Data. LSB = 1˚C. Two’s complement format.
For RTLB D7–D5: Temperature Data. LSB = 0.125˚C. Two’s complement format.
The maximum value available from the Local Temperature register is 127; the minimum value available from the Local
Temperature register is -128. The maximum value available from the Remote Temperature register is 127.875; the minimum value
available from the Remote Temperature registers is −128.875.
2.3 STATUS REGISTER (SR)
Power up default is with all bits “0” (zero).
D0: LCRIT: When set to “1” indicates a Local Critical Temperature alarm.
D1: RCRIT: When set to “1” indicates a Remote Diode Critical Temperature alarm.
D2: OPEN: When set to “1” indicates a Remote Diode disconnect.
D3: RLOW: When set to “1” indicates a Remote Diode LOW Temperature alarm
D4: RHIGH: When set to “1” indicates a Remote Diode HIGH Temperature alarm.
D5: LLOW: When set to “1” indicates a Local LOW Temperature alarm.
D6: LHIGH: When set to “1” indicates a Local HIGH Temperature alarm.
D7: Busy: When set to “1” ADC is busy converting.
Read Address
<
P7:P0
B0h-BEh
Command Select Address
BFh
FEh
FFh
11h
12h
13h
14h
19h
20h
21h
>
(Read Only Address 02h):
hex
Busy
D7
Write Address
<
P7:P0
B0h-BEh
(Read Only Address 00h, 01h):
(Read Only Address 10h):
LHIGH
BFh
12h
13h
14h
19h
20h
21h
11h
Value
Value
NA
NA
BIT
BIT
D6
>
hex
SIGN
(Continued)
0.5
D7
D7
LLOW
<
D5
D7:D0
0000 0000
0000 0000
0000 0000
0000 0000
0101 0101
0101 0101
0000 1010
0000 0000
0000 0001
0001 0001
0.25
D6
D6
64
Power On Default State
>
binary
RHIGH
0.125
D5
D5
D4
32
14
D4
D4
16
0
<
decimal
RLOW
D7:D0
D3
85
85
10
17
0
0
0
0
0
1
D3
D3
8
0
>
OPEN
D2
D2
4
0
D2
Register
RTOHB
RHSLB
RTOLB
RLSLB
Name
RDTF
RMID
RCS
RDR
LCS
TH
D1
D1
2
0
RCRIT
D1
D0
D0
1
0
Remote Temperature Offset
High Byte
Remote Temperature Offset
Low Byte
Remote HIGH Setpoint Low
Byte
Remote LOW Setpoint Low
Byte
Remote T_CRIT Setpoint
Local T_CRIT Setpoint
T_CRIT Hysteresis
Manufacturers Test Registers
Remote Diode Temperature
Filter
Read Manufacturer’s ID
Read Stepping or Die Revision
Code
Register Function
LCRIT
D0

Related parts for LM86CIM/NOPB