LM86CIM/NOPB National Semiconductor, LM86CIM/NOPB Datasheet - Page 11

IC TEMP SENSOR DGTL 8-SOIC

LM86CIM/NOPB

Manufacturer Part Number
LM86CIM/NOPB
Description
IC TEMP SENSOR DGTL 8-SOIC
Manufacturer
National Semiconductor
Datasheets

Specifications of LM86CIM/NOPB

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Supply Current
800µA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
SOIC
No. Of Pins
8
Filter Terminals
SMD
Rohs Compliant
Yes
Accuracy %
1°C
For Use With
LM86EVAL/NOPB - BOARD EVALUATION LM86
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1.0 Functional Description
1.10 SERIAL INTERFACE RESET
In the event that the SMBus Master is RESET while the
LM86 is transmitting on the SMBData line, the LM86 must be
returned to a known state in the communication protocol.
This may be done in one of two ways:
1. When SMBData is LOW, the LM86 SMBus state ma-
chine resets to the SMBus idle state if either SMBData
or SMBCLK are held low for more than 35ms (t
Note that according to SMBus specification 2.0 all de-
vices are to timeout when either the SMBCLK or SMB-
Data lines are held low for 25-35ms. Therefore, to insure
a timeout of all devices on the bus the SMBCLK or
SMBData lines must be held low for at least 35ms.
(c) Serial Bus Read from a Register with the Internal Command Register preset to desired value.
(a) Serial Bus Write to the internal Command Register followed by a the Data Byte
(b) Serial Bus Write to the Internal Command Register
FIGURE 7. SMBus Timing Diagrams
(Continued)
TIMEOUT
).
11
1.9.1 SMBus Timing Diagrams
2. When SMBData is HIGH, have the master initiate an
1.11 DIGITAL FILTER
In order to suppress erroneous remote temperature readings
due to noise, the LM86 incorporates a user-configured digital
filter. The filter is accessed in the FILTER and ALERT CON-
FIGURE REGISTER at BFh. The filter can be set according
to the following table.
SMBus start. The LM86 will respond properly to an
SMBus start condition at any point during the communi-
cation. After the start the LM86 will expect an SMBus
Address address byte.
10130310
10130311
10130312
www.national.com