W83792G Nuvoton Technology Corporation of America, W83792G Datasheet - Page 32

no-image

W83792G

Manufacturer Part Number
W83792G
Description
IC MONITOR H/W 48-LQFP
Manufacturer
Nuvoton Technology Corporation of America
Datasheet

Specifications of W83792G

Function
Hardware Monitor
Topology
ADC, Fan Control, Register Bank
Sensor Type
External
Sensing Temperature
External Sensor
Output Type
I²C™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W83792G
Manufacturer:
Nuvoton Technology Corporation of America
Quantity:
10 000
Part Number:
W83792G
Manufacturer:
WINBOND/PBF
Quantity:
625
Part Number:
W83792GЈ¬ CЈ¬ 1E
Manufacturer:
Winbond
Quantity:
1 000
7.7.5
SMI# interrupt for voltage is Two-Times Interrupt Mode. Voltage exceeding high limit or going below
low limit will causes an interrupt if the previous interrupt has been reset by reading all the interrupt
Status Register. (Figure 10-1.)
7.7.6
SMI# interrupt for fan is Two-Times Interrupt Mode. Fan count exceeding the limit, or exceeding and
then going below the limit, will causes an interrupt if the previous interrupt has been reset by reading
all the interrupt Status Register. (Figure 10-2.)
7.7.7
(1) Comparator Interrupt Mode
Temperature exceeding T
Interrupt Status Register. Once an interrupt event has occurred by exceeding T
temperature remains above the T
completed. If an interrupt event has occurred by exceeding T
will not occur again. The interrupts will continue to occur in this manner until the temperature goes
below T
Temperature exceeding T
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status Register.
Once an interrupt event has occurred by exceeding T
the T
(3) One-Time interrupt mode
Temperature exceeding T
an interrupt. Once an interrupt event has occurred by exceeding T
interrupt will not occur again until the temperature exceeding T
(2) Two-Times Interrupt Mode
HYST
HYST
SMI# interrupt for W83792D/G Voltage
SMI# interrupt for W83792D/G Fan
SMI# interrupt for W83792D/G temperature sensor 1/2/3
SMI#
, the interrupt will not occur. (Figure 10-4.)
Low limit
High limit
. (Figure 10-3.)
Figure 10-1. Voltage SMI# Mode
O
*
O
O
causes an interrupt and then temperature going below T
causes an interrupt and then temperature going below T
causes an interrupt and this interrupt will be reset by reading all the
*
HYST
, the interrupt will occur again when the next conversion has
*
*Interrupt Reset when Interrupt Status Registers are read
*
- 26 -
O
, then reset, if the temperature remains above
O
O
Fan Count limit
. (Figure 10-5.)
but has not been reset, the interrupts
SMI#
W83792AD/AG/D/G
Figure 10-2. Fan SMI# Mode
O
, then going below T
O
, then reset, if the
*
HYST
will not cause
HYST
*
will also
HYST,
an

Related parts for W83792G