IC THERM/EEPROM DIG 256BYTE 8DIP

DS1624+

Manufacturer Part Number
DS1624+
Description
IC THERM/EEPROM DIG 256BYTE 8DIP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1624+

Function
Thermometer, Thermostat
Topology
EEPROM, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
2-Wire Serial
Output Alarm
No
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Full Temp Accuracy
+/- 0.5 C
Digital Output - Bus Interface
2-Wire, SMBus
Digital Output - Number Of Bits
13 bit
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Supply Current
1000 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
During the programming cycle the DS1624 will not acknowledge any further accesses to the device until
the programming cycle is complete (approximately 10 ms).
MEMORY FUNCTION EXAMPLE
{Command protocol for configuration register}
{Start here}
{Command protocol for Start Convert T}
{Start here}
{Command protocol for reading the Temperature}
{Start here}
BUS MASTER
MODE
RX
RX
RX
RX
RX
RX
RX
RX
RX
RX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
TX
DS1624
MODE
RX
RX
RX
RX
RX
TX
RX
TX
RX
TX
RX
RX
TX
RX
TX
RX
RX
TX
RX
TX
RX
TX
TX
RX
TX
DATA (MSB
<cadr,0>
<cadr,0>
<cadr,0>
<cadr,1>
FIRST)
START
START
START
START
<data>
<data>
STOP
STOP
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACh
AAh
EEh
00h
11 of 17
Bus Master Initiates a Start condition.
Bus Master sends DS1624 address;
R/
DS1624 generates acknowledge bit.
Bus Master sends Access Config
command protocol.
DS1624 generates acknowledge bit.
Bus Master sets up DS1624 for continuous
conversion.
DS1624 generates acknowledge bit.
Bus Master initiates the STOP condition.
Bus Master initiates a Start condition.
Bus Master sends DS1624 address;
R/
DS1624 generates acknowledge bit.
Bus Master sends Start Convert T
command protocol.
DS1624 generates acknowledge bit.
Bus Master initiates the STOP condition.
Bus Master initiates a Start condition.
Bus Master sends DS1624 address;
R/
DS1624 generates acknowledge bit.
Bus Master sends Read Temp command
protocol.
DS1624 generates acknowledge bit.
Bus Master initiates a Repeated Start
condition.
Bus Master sends DS1624 address;
R/
DS1624 generates acknowledge bit.
DS1624 sends the MSB byte of
Temperature.
Bus Master generates acknowledge bit.
DS1624 sends the LSB byte of
Temperature.
W
W
W
W
=”0”;
=0;
=0;
=1;
COMMENTS
NOTES
2, 4
DS1624
1
1
1