LM96000CIMT/NOPB National Semiconductor, LM96000CIMT/NOPB Datasheet - Page 22

IC HDWR MON W/FAN CTRL 24-TSSOP

LM96000CIMT/NOPB

Manufacturer Part Number
LM96000CIMT/NOPB
Description
IC HDWR MON W/FAN CTRL 24-TSSOP
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheet

Specifications of LM96000CIMT/NOPB

Function
Fan Control, Temp Monitor
Topology
ADC (Sigma Delta), Comparator, Fan Control, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP
Ic Output Type
Digital
Sensing Accuracy Range
± 2.5°C
Temperature Sensing Range
0°C To +85°C
Supply Current
530µA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
8bit
Sensor Case Style
TSSOP
No. Of Pins
24
Rohs Compliant
Yes
Accuracy %
3°C
For Use With
LM96000EVAL - BOARD EVALUATION LM96000
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM96000CIMT
*LM96000CIMT/NOPB
LM96000CIMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM96000CIMT/NOPB
Manufacturer:
EPCOS
Quantity:
3 186
www.national.com
Register
Address
5Fh
60h
61h
4.15 Registers 5F-61h: Auto Fan Speed Range, PWM Frequency
In Auto Fan Mode, when the temperature for a zone is above the Temperature Limit (Registers 67-69h) and below its Absolute
Temperature Limit (Registers 6A-6Ch), the speed of a fan assigned to that zone is determined as follows.
When the temperature reaches the Fan Temp Limit for a zone, the PWM output assigned to that zone will be Fan PWM Minimum.
Between Fan Temp Limit and (Fan Temp Limit + Range), the PWM duty cycle will increase linearly according to the temperature
as shown in the figure below. The PWM duty cycle will be 100% at (Fan Temp Limit + Range).
Example for PWM1 assigned to Zone 1:
In this case, the PWM1 duty cycle will be 50% at 50°C.
Since (Zone 1 Fan Temp Limit) + (Zone 1 Range) = 50°C + 8°C = 58°C, the fan will run at 100% duty cycle when the temperature
of the Zone 1 sensor reaches 58°C.
Since the midpoint of the fan control range is 54°C, and the median duty cycle is 75% (Halfway between the PWM Minimum and
100%), PWM1 duty cycle would be 75% at 54°C.
Above (Zone 1 Fan Temp Limit) + (Zone 1 Range), the duty cycle will be 100%.
PWM frequency bits [3:0]
The PWM frequency bits [3:0] determine the PWM frequency for the fan.The LM96000 has high and low frequency ranges for the
PWM outputs, that are controlled by the HLFRQ bit.
PWM Frequency Selection (Default = 0011 = 30.04 Hz).
– Zone 1 Fan Temp Limit (Register 67h) is set to 50°C (32h).
– Range (Register 5Fh) is set to 8°C (6xh).
– Fan 1 PWM Minimum (Register 64h) is set to 50% (32h).
Read/
Write
R/W
R/W
R/W
Register
Name
Zone1 Range/Fan1
Frequency
Zone2 Range/Fan2
Frequency
Zone3 Range/Fan3
Frequency
FIGURE 1. Fan Activity above Fan Temp Limit
Bit 7
(MSB)
RAN3
RAN3
RAN3
Bit 6
RAN2
RAN2
RAN2
Bit 5
RAN1
RAN1
RAN1
22
Bit 4
RAN0
RAN0
RAN0
Bit 3
HLFRQ
HLFRQ
HLFRQ
Bit 2
FRQ2
FRQ2
FRQ2
Bit 1
FRQ1
FRQ1
FRQ1
Bit 0
(LSB)
FRQ0
FRQ0
FRQ0
20084606
Default
Value
C4h
C4h
C4h
Lock?

Related parts for LM96000CIMT/NOPB