LM63CIMA/NOPB National Semiconductor, LM63CIMA/NOPB Datasheet - Page 19
![IC TEMP SENSR REMOTE DIODE 8SOIC](/photos/6/56/65640/pkg_m08a_sml.jpg)
LM63CIMA/NOPB
Manufacturer Part Number
LM63CIMA/NOPB
Description
IC TEMP SENSR REMOTE DIODE 8SOIC
Manufacturer
National Semiconductor
Series
PowerWise®r
Datasheet
1.LM63CIMANOPB.pdf
(30 pages)
Specifications of LM63CIMA/NOPB
Function
Fan Control, Temp Monitor
Topology
ADC (Sigma Delta), Comparator, Fan Speed Control, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 85°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Ic Output Type
Digital
Sensing Accuracy Range
± 1°C
Supply Current
1.3mA
Supply Voltage Range
3V To 3.6V
Resolution (bits)
11bit
Sensor Case Style
SOIC
No. Of Pins
8
Termination Type
SMD
Rohs Compliant
Yes
Filter Terminals
SMD
Accuracy %
1°C
For Use With
LM63EVAL - BOARD EVALUATION LM63
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM63CIMA
LM63CIMA
LM63CIMA
03 (09)
Address
03 (09)
Configuration Register
Hex
HEX
CONFIGURATION REGISTER
Read/
Write
R/W
Bits
4:3
7
6
5
2
1
0
Value
POR
00
0
0
0
0
0
0
PWM Disable
T_CRIT Limit
in STANDBY
ALERT/Tach
RDTS Fault
STANDBY
Override
ALERT
Queue
Name
Select
Mask
When this bit is a 0, ALERT interrupts are enabled.
When this bit is set to a 1, ALERT interrupts are masked, and the ALERT pin is
always in a high impedance (open) state.
When this bit is a 0, the LM63 is in operational mode, converting, comparing,
and updating the PWM output continuously.
When this bit is a 1, the LM63 enters a low power standby mode.
In STANDBY, continuous conversions are stopped, but a conversion/
comparison cycle may be initiated by writing any value to register 0x0F.
Operation of the PWM output in STANDBY depends on the setting of bit 5 in
this register.
When this bit is a 0, the LM63’s PWM output continues to output the current fan
control signal while in STANDBY.
When this bit is a 1, the PWM output is disabled (as defined by the PWM polarity
bit) while in STANDBY.
These bits are unused and always set to 0.
When this bit is a 0, the ALERT/Tach pin is an open drain ALERT output.
When this bit is a 1, the ALERT/Tach pin is a high impedance Tachometer input.
Note that if this bit is set, the function of the ALERT/Tach pin must be Tach input,
so an external ALERT condition will not occur.
The T_CRIT limit for the remote diode is nominally 85°C. This value can be
changed once after power-up by first setting this bit to a 1, then programming
a new T_CRIT value into the Remote Diode T_CRIT Limit (register 0x19). The
T_CRIT value can not be changed again except by cycling power to the LM63.
0: an ALERT will be generated if any Remote Diode conversion result is above
the Remote High Set Point or below the Remote Low Setpoint.
1: an ALERT will be generated only if three consecutive Remote Diode
conversions are above the Remote High Set Point or below the Remote Low
Setpoint.
19
Description
www.national.com