Specifications of STLM75M2F

Function
Temp Sensor, Watchdog
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire, I2C)
Digital Output - Number Of Bits
12 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
For Use With
497-10508 - BOARD EVAL FOR MEMS SENSORS497-10048 - BOARD EVAL ACCELEROMETER497-8848 - EVAL DAUGHTER STLM75 8-SOIC497-6238 - BOARD STLM75/STDS75/ST72F651
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6926-2
STLM75M2F

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STLM75M2F
Manufacturer:
STMicroelectronics
Quantity:
1 850
Part Number:
STLM75M2F
Manufacturer:
STM
Quantity:
280
Part Number:
STLM75M2F
Manufacturer:
ST
0
Part Number:
STLM75M2F
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
STLM75M2F
Quantity:
2 500
STLM75
3.4.4
Data valid
The state of the data line represents valid data when after a start condition, the data line is
stable for the duration of the high period of the clock signal. The data on the line may be
changed during the low period of the clock signal. There is one clock pulse per bit of data.
Each data transfer is initiated with a start condition and terminated with a stop condition.
The number of data bytes transferred between the start and stop conditions is not limited.
The information is transmitted byte-wide and each receiver acknowledges with a ninth bit.
By definition a device that gives out a message is called “transmitter”, the receiving device
that gets the message is called “receiver”. The device that controls the message is called
“master”. The devices that are controlled by the master are called “slaves”.
Figure 6.
CLOCK
DATA
CONDITION
Serial bus data transfer sequence
START
Doc ID 13296 Rev 12
DATA VALID
DATA LINE
STABLE
DATA ALLOWED
CHANGE OF
Functional description
CONDITION
STOP
AI00587