MAX1946ETA+T Maxim Integrated Products, MAX1946ETA+T Datasheet - Page 8

IC SW USB SNGL W/FB 8-TDFN

MAX1946ETA+T

Manufacturer Part Number
MAX1946ETA+T
Description
IC SW USB SNGL W/FB 8-TDFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1946ETA+T

Applications
USB, Peripherals
Current - Supply
40µA
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-TDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The MAX1946 includes output current limiting, short-cir-
cuit protection, thermal shutdown, an enable input, and
fault indicator (see the Functional Diagram ). A logic
input at SEL sets the active polarity of the enable input.
The fault indicator notifies the system when the current-
limit, short-circuit, undervoltage lockout, or thermal-
shutdown threshold is exceeded.
Single USB Switch with Autoreset and
Fault Blanking in Tiny TDFN
(Circuit of Figure 2, V
8
_______________________________________________________________________________________
PIN
3, 4
5, 6
1
2
7
8
C
D
A
B
A: V
B: V
C: V
D: I
OUT
OUT
FAULT
OUT
FAULT
NAME
, 500mA/div
, 5V/div
, 2V/div
GND
OUT
IN
SEL
ON
, 5V/div
EP
C
R
IN
STARTUP WAVEFORMS
OUT
OUT
= 5V, C
= 10Ω
= 100µF
Detailed Description
C
OUT
1ms/div
= 100µF
IN
Fault-Indicator Output Switch. Open-drain output asserts low when switch enters thermal shutdown,
undervoltage lockout, or a sustained (>20ms) current-limit or short-circuit condition.
Ground
Switch Power Output. Connect OUT pins together at the device and bypass with a 1µF ceramic
capacitor. Load conditions may require additional bulk capacitance. When disabled, OUT goes into
a high-impedance state.
Switch Power Input. Connect IN pins together at the device and bypass with a 0.1µF ceramic
capacitor to GND. Input conditions may require additional bulk capacitance to prevent pulling the
input supply down.
ON/OFF Control Input. The active polarity of ON is set by SEL. Connect SEL high to make ON active
high. Connect SEL to GND to make ON active low.
Logic Input Polarity Select. SEL sets the active polarity of the ON input. Connect SEL high to make
ON active high. Connect SEL to GND to make ON active low.
Exposed Metal Paddle. This paddle is internally connected to GND through a soft connect. For
enhanced thermal dissipation, connect EP to a large ground plane. Do not use EP as a sole ground
connection.
= 0.1µF, C
MAX1946 toc21
OUT
Typical Operating Characteristics (continued)
= 1µF, ON = SEL, T
0
0
0
0
A
The MAX1946 operates from a 2.7V to 5.5V input
supply and supplies a minimum output current of 740mA.
A built-in current limit of 1.1A limits the output current in
the event of an overload condition. A built-in short-circuit
detection circuit pulses the output current if the output
voltage falls below 1V. This lowers RMS output current
and reduces power dissipation during continuous short
conditions.
= +25°C, unless otherwise noted.)
FUNCTION
A
B
C
A: V
B: V
C: V
IN
OUT
FAULT
, 2V/div
, 2V/div
, 2V/div
UVLO RESPONSE
10ms/div
Pin Description
MAX1946 toc22
0
0
0

Related parts for MAX1946ETA+T