MCZ33800EK Freescale Semiconductor, MCZ33800EK Datasheet - Page 26

no-image

MCZ33800EK

Manufacturer Part Number
MCZ33800EK
Description
IC ENGINE CTRL SW/DVR 54-SOIC
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MCZ33800EK

Applications
Automotive
Current - Supply
10mA
Voltage - Supply
5 V ~ 36 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
54-SOIC (7.5mm Width) Exposed Pad, 54-eSOIC, 54-HSOIC
Product
Fan / Motor Controllers / Drivers
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCZ33800EK
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MCZ33800EK
Manufacturer:
FREESCALE
Quantity:
2 430
Part Number:
MCZ33800EK
Manufacturer:
FREESCALE
Quantity:
2 430
Part Number:
MCZ33800EK
Manufacturer:
FREESCALE
Quantity:
20 000
temperature of the output driver to determine the fault. Both
methods may be selected or used individually. The following
table provides an explanation of operation during fault
condition.
set by the fault timer used to detect the short circuit. For short
circuits detected based on the output voltage exceeding the
fault detection voltage threshold, the outputs will be turned off
for the duration of the refresh timer (typically 10ms) and
turned on for the duration of the on-state short circuit fault
timer (typically 500µs). For short circuits detected based on
the output current exceeding the output current limit, the
outputs will be turned off for the duration of the refresh timer
(typically 10 ms) and turned on for the duration of the current
limit fault timer (typically 50µs).
off-open fault is released and re-detected every 1-2 retry
timer periods. Retry timer for 1-2, 3-4, 5-6, and 7-8 are out of
phase and may report a load present, if the OSS read
command CS is issued after the release, and before the re-
detection (~500µs) of the off-state open load fault.
Table 13. TLim/Timer Control
limit is always active in Normal Mode. Current limit for OUT1
and OUT2 is 4.0 to 6.0A. Current limit for OUT3 through
OUT8 is 1.0 to 2.0A.
26
33800
FUNCTIONAL DEVICE OPERATION
LOGIC COMMANDS AND REGISTERS
Retry Bit
The low duty cycle used for the timer protection scheme is
For off-state open load faults with retry timer enabled, the
All OSS outputs have a current limit control loop. Current
Shutdn
1
1
1
0
0
0
TLIM
Bit
0
1
1
0
1
1
Timer
Fault
Bit
X
X
0
1
0
1
Timer only, Outputs will retry on
period
OUT1-8 = ~500us for short
circuit faults, and 50us for current
limit faults ON, ~10ms OFF.
TLim only, Outputs will retry on
TLim hysteresis.
Timer and TLim, Outputs will
retry on period and driver
temperature below threshold.
OUT1-8 = ~500us ON, ~10ms
OFF
Timer only, Outputs will not retry
on period
OUT1-8 = ~500us ON, OFF
TLim only, Outputs will not retry
on TLim hysteresis.
Timer and TLim, Outputs will not
retry on period or TLim.
OUT1-8 = ~500us ON, OFF
Operation During Short Fault
PARALLEL OUTPUT, PX PIN ENABLE COMMAND
output for increased current capability and enables control of
the PX input pin.
individual control. Logic 1 commands outputs to operate in
parallel. For example, with bit 4 in the Parallel Output
command a logic 1, outputs 1 & 2 are controlled together
1 on SPI bit 0 or SPI bit 1 will command both outputs on.
Similarly a logic 1 on the P1 pin will command both outputs
on.
P1, P3, P5, P7 pins respectively. A logic 0 in the SPI word will
enable the PX input pin, while logic 1 in the SPI word will
disable the PX input pin. Default state is with the PX input
pins enabled.
maintained at 4.0 to 6.0A. Parallel current limit for drivers
3&4, 5&6, 7&8 is increased to a range of 2.0 to 4.0A.
connection of paired outputs. The R
devices have inherent positive temperature coefficient
providing balanced current sharing between outputs without
destructive operation. This mode of operation may be
desirable in the event the application requires lower power
dissipation or the added capability of switching higher
currents. Performance of parallel operation results in a
corresponding decrease in R
Limit increases correspondingly. Output OFF Open Load
Detect current may increase based on how the Output OFF
Open Load Detect is programmed.
Table 14. And/Or/SPI/Parallel Control
Parallel
En Bit
The Parallel Output command allows the user to parallel
A logic 0 in the Parallel Output Command provides
With the outputs paralleled, and the P1 pin enabled, a logic
PX pin Enable bit 0 through bit 3 enables or disables the
When paralleling output 1 & 2 the current limit is
Using a MOSFET as output switches allows the
1
1
1
1
1
1
1
1
1
1
1
1
1
PX Pin
En Bit
0
0
0
0
1
1
1
1
1
1
1
1
1
PX Pin
Analog Integrated Circuit Device Data
X
X
X
X
X
0
0
0
0
0
1
1
1
DS(ON)
OR Bit
0(and)
0(and)
0(and)
0(and)
0(and)
AND/
1(or)
1(or)
1(or)
1(or)
X
X
X
X
Freescale Semiconductor
, while the Output Current
DS(ON)
Bit 1
SPI
X
0
0
1
1
0
0
1
1
0
0
1
1
of MOSFET
Bit 0
SPI
X
0
1
0
1
0
1
0
1
0
1
0
1
Output
OFF
OFF
OFF
OFF
1&2
ON
ON
ON
ON
ON
ON
ON
ON
ON

Related parts for MCZ33800EK