AMIS30623C623BRG ON Semiconductor, AMIS30623C623BRG Datasheet - Page 43

IC MOTOR DRIVER/CTLR 32-QFP

AMIS30623C623BRG

Manufacturer Part Number
AMIS30623C623BRG
Description
IC MOTOR DRIVER/CTLR 32-QFP
Manufacturer
ON Semiconductor
Datasheet

Specifications of AMIS30623C623BRG

Applications
Stepper Motor Driver
Number Of Outputs
1
Current - Output
800mA
Voltage - Supply
6.5 V ~ 29 V
Operating Temperature
-40°C ~ 165°C
Mounting Type
Surface Mount
Package / Case
32-VSQFP
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Load
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS30623C623BRG
Manufacturer:
ON Semiconductor
Quantity:
1 850
Part Number:
AMIS30623C623BRG
Manufacturer:
ON Semiconductor
Quantity:
10 000
LIN Lost Before or At Power On
<ActPos> register does not reflect the “real” actual
position. So at LIN – lost a referencing is started using
DualPositioning. A first negative motion for half the
will be followed. See Figure 25.
If the LIN communication is lost before or at power on, the
If LIN is lost before or at power on, following sequence
1. If the LIN communication is lost AND
2. If the LIN communication is lost AND
<FailSafe> = 0, secure positioning will be
done at absolute position (stored secure position
<SecPos>.) Depending on SleepEn
AMIS−30623 will enter the <Stop> state or
<Sleep> state. See Table 35.
<FailSafe> = 1 a referencing is started using
DualPositioning, meaning a negative motion for
half the positioner range is initiated until the stall
position is reached. The motion parameters stored
in OTP will be used for this. After this mechanical
end position is reached <ActPos> will be reset to
zero. The direction of the motion is given by the
Shaft bit.
− If <SecPos[10:0]> = 0x400:
No Second Motion will be performed.
Figure 25. Case B: LIN Lost at or During Start−Up
STOP
No
At Stall −> ActPos = ‘0000’
to SecPos stored in RAM,
First motion of DualPosition
Half the position range
Secure Positioning
copied from OTP
Negative direction
SecPos ≠ 0x400
http://onsemi.com
SleepEn = 1
FailSafe = 1
SLEEP
Yes
Yes
Yes
B
43
positioner range is initiated until the stall position is reached.
The motion parameters stored in OTP will be used for this.
After this mechanical end position is reached, <ActPos>
will be reset to zero. A second motion will start to the Secure
Position also stored in OTP. More details are given below.
Depending on SleepEn AMIS−30623 will enter the
<Stop> state or <Sleep> state. See Table 35.
Important Remarks:
No
No
1. The Secure Position has only a resolution of 9 bit
2. The motion direction to SecPos is given by the
3. In case of HW2 float (= lost LIN address), the
STOP
because only the 9 MSB’s will be copied from
OTP to RAM. See also Secure Position
Shaft bit in OTP.
behavior is the same as described above, except
for going to sleep mode. In that case failsafe
operation due to HW2 float is not leading to the
sleep state, otherwise the LIN communication will
wake−up the node and cycling through POR will
occur. See also Hardwired Address HW2.
− If <SecPos[10:0]> ≠ 0x400:
A second motion to <SecPos> is performed.
The direction is given by <SecPos[10]> in
combination with <Shaft>. Motion is done
with parameters from OTP.

Related parts for AMIS30623C623BRG