BTS308 E3059 Infineon Technologies, BTS308 E3059 Datasheet
BTS308 E3059
Specifications of BTS308 E3059
SP000011226
Related parts for BTS308 E3059
BTS308 E3059 Summary of contents
Page 1
Smart Highside Power Switch Features Overload protection Current limitation Short circuit protection Thermal shutdown Overvoltage protection (including load dump) Fast demagnetization of inductive loads 1 ) Reverse battery protection Undervoltage and overvoltage shutdown with auto-restart and hysteresis Open drain diagnostic ...
Page 2
Pin Symbol 1 GND - OUT O (Load, L) Maximum Ratings °C unless otherwise specified j Parameter Supply voltage (overvoltage protection see page 3) Load ...
Page 3
Electrical Characteristics Parameter and Conditions ° unless otherwise specified j bb Load Switching Capabilities and Characteristics On-state resistance (pin 0 12V ...
Page 4
Parameter and Conditions ° unless otherwise specified Protection Functions Initial peak short circuit current limit (pin max 100 > ON(SC) ...
Page 5
Parameter and Conditions ° unless otherwise specified j bb Input and Status Feedback Input resistance see circuit page 6 Input turn-on threshold voltage Input turn-off threshold voltage Input threshold hysteresis, T Off ...
Page 6
Truth Table Input- Output level level Normal L L operation Open load Short circuit GND H L Short circuit Overtem perature ...
Page 7
Inductive and overvoltage output clamp V Z PROFET GND V clamped typ. ON Overvolt. and reverse batt. protection Logic GND V = 6.2 V typ., V ...
Page 8
V disconnect with charged external bb inductive load high OUT PROFET GND other external inductive loads L are connected to the PROFET, additional elements like D are ...
Page 9
Options Overview all versions: High-side switch, Input protection, ESD protection, load dump and reverse battery protection with 150 Type Logic version Overtemperature protection with hysteresis >150 °C, latch function ) T j >150 °C, with auto-restart ...
Page 10
Timing diagrams Figure 1a: V turn on d(bb IN OUT A ST open drain A in case of too early V IN =high the device may not turn on (curve A) t approx. 150 ...
Page 11
Figure 3c: Short circuit while on OUT I L **) **) current peak approx Figure 4a: Overtemperature, Reset if (IN=low) and (T < OUT goes ...
Page 12
Figure 6b: Undervoltage restart of charge pump bb(o rst) bb(u rst) V bb(u cp) V bb(under) charge pump starts at V =4.9 V typ. bb(ucp) Figure 7a: Overvoltage ON(CL) bb(over) bb ...
Page 13
Package and Ordering Code All dimensions in mm Standard TO-220AB/5 BTS 308 TO-220AB/5, Option E3043 BTS 308 E3043 Semiconductor Group SMD TO-220AB/5, Opt. E3062 Ordering code BTS 308 E3062A tbd Ordering code tbd Page 13 BTS 308 Ordering code T&R: ...
Page 14
... Office. Infineon Technologies Components may only be used in life- support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life- support device or system affect the safety or effectiveness of that device or system. Life support devices ...