Specifications of L9822E

Input Type
SPI
Number Of Outputs
8
On-state Resistance
550 mOhm
Current - Peak Output
1.05A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
Multiwatt-15 (Vertical, Bent and Staggered Leads)
Rise Time
50 ns
Fall Time
50 ns
Supply Voltage (min)
- 0.7 V
Supply Current
10 mA
Maximum Operating Temperature
+ 150 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Number Of Drivers
8
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output / Channel
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-3660-5
497-3935-5
497-3935-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L9822E
Manufacturer:
ST
Quantity:
5 510
Part Number:
L9822E
Manufacturer:
NEC
Quantity:
5 510
Part Number:
L9822E
Manufacturer:
ST
0
Part Number:
L9822EPD
Manufacturer:
ST
Quantity:
5 510
Part Number:
L9822EPD
Manufacturer:
ST
Quantity:
20 000
Part Number:
L9822EPD013
Manufacturer:
ST
0
Part Number:
L9822EPD013TR
Manufacturer:
ST
0
Part Number:
L9822EPD013TR
Manufacturer:
ST
Quantity:
20 000
Functional description
4.6
12/17
Fault conditions check
Checking for fault conditions may be done in the following way. Clock in a new control byte.
Wait 160 µs or so to allow the outputs to settle.
Clock in the same control byte and observe the diagnostic data that comes out of the device.
The diagnostic bits should be identical to the bits that were first clocked in. Any differences
would point to a fault on that output. If the output was programmed ON by clocking in a zero,
and a one came back as the diagnostic bit for that output, the output pin was still high and a
short circuit or overload condition exists.
If the output was programmed OFF by clocking in a one, and a zero came back as the
diagnostic bit for that output, nothing had pulled the output pin high and it must be floating,
so an open circuit condition exists for that output.
Figure 4.
Figure 5.
OUTPUTS
RESET
OUTS
SCLK
SCLK
SI
CE
SO
CE
SO
SI
Byte timing with asynchronous reset.
Timing diagram.
TEN
TLEAD
#7
#7
#7
TV
#6
#6
TSU
OLD
I/FOP
TWSCKL
DI7
#5
#5
TH
D07
OLD
TWSCKH
#4
#4
#6
#3
#3
D06
#2
#2
#1
#1
THD
#0
#0
TLAG
DI0
D00
NEW
TDIS
TPHL
TPLH
FAULTS
TUD
FAULT-INDUCED
NEW
TURN/OFF
RESET
L9822E

Related parts for L9822E