BTS443P Infineon Technologies, BTS443P Datasheet

SWITCH HIGH SIDE POWER TO252-5

BTS443P

Manufacturer Part Number
BTS443P
Description
SWITCH HIGH SIDE POWER TO252-5
Manufacturer
Infineon Technologies
Series
PROFET®r
Type
High Sider
Datasheets

Specifications of BTS443P

Input Type
Non-Inverting
Number Of Outputs
1
On-state Resistance
13 mOhm
Current - Output / Channel
25A
Current - Peak Output
65A
Voltage - Supply
5 V ~ 36 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DPak, TO-252 (4 leads + tab)
Power Load Switch Type
High Side
Input Voltage
36V
On Resistance Rds(on)
0.016ohm
Thermal Protection
ESD
Power Dissipation Pd
42W
No. Of Outputs
1
Internal Switch
No
Distribution
RoHS Compliant
Current Limit
65A
On State Resistance
0.013ohm
Rohs Compliant
Yes
Distribution Switch Case Style
P-TO252-5
On Resistance (max)
0.013 Ohms
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Maximum Power Dissipation
42000 mW
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
BTS443PINTR
BTS443PT
BTS443PXT
BTS443PXTINTR
BTS443PXTINTR
SP000012530
SP000264198

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS443P
Manufacturer:
FREESCALE
Quantity:
201
Part Number:
BTS443P
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS443P
0
Part Number:
BTS443P4287AB
Manufacturer:
INF
Quantity:
1 200
Smart Highside Power Switch
Reversave
• Reverse battery protection by self turn on of
Features
• Short circuit protection
• Current limitation
• Overload protection
• Thermal shutdown
• Overvoltage protection (including load dump)
• Loss of ground protection
• Loss of V
• Very low standby current
• Fast demagnetisation of inductive loads
• Electrostatic discharge (ESD) protection
• Optimized static electromagnetic compatibility (EMC)
• Green product (RoHS compliant)
• AEC qualified
Diagnostic Function
• Proportional load current sense (with defined fault signal during thermal shutdown)
Application
• Power switch with current sense diagnostic feedback for 12V and 24 V DC grounded loads
• All types of resistive, capacitive and inductive loads (no PWM with inductive loads)
• Replaces electromechanical relays, fuses and discrete circuits
General Description
N channel vertical power FET with charge pump, current controlled input and diagnostic feedback with load
current sense, integrated in Smart SIPMOS  chip on chip technology. Providing embedded protective functions.
Data Sheet
power MOSFET
charged inductive loads)
I
IN
2
bb
Logic GND
V
IN
protection (with external diode for
IN
V
IS
ESD
4
IS
Voltage
Voltage
sensor
source
Logic
I
R
IS
IS
Overvoltage
protection
Charge pump
Level shifter
Rectifier
Page 1 of 15
Current
Product Summary
Operating voltage
On-state resistance
Load current (ISO)
Current limitation
Package
PG-TO252-5-11
limit
Temperature
unclamped
ind. loads
detection
Voltage
Limit for
Output
sensor
protection
Gate
R bb
Current
Sense
PROFET ® BTS 443 P
PROFET
V
R
I
I
L(ISO)
L(SCr)
bb(on)
ON
+ V bb
OUT
Rev. 1.0, 2007-02
3 & Tab
1, 5
I
5.0 ... 36
L
Load GND
Load
16 mΩ
25
65
V
A
A

Related parts for BTS443P

BTS443P Summary of contents

Page 1

Smart Highside Power Switch Reversave • Reverse battery protection by self turn on of power MOSFET Features • Short circuit protection • Current limitation • Overload protection • Thermal shutdown • Overvoltage protection (including load dump) • Loss of ground ...

Page 2

Pin Symbol 1 OUT Tab/( OUT O *) Not shorting all outputs will considerably increase the on-state resistance, reduce the peak current capability and decrease the current sense accuracy ...

Page 3

Thermal Characteristics Parameter and Conditions Thermal resistance junction - ambient (free air): R SMD version, device on PCB Electrical Characteristics Parameter and Conditions -40°C...150° unless otherwise specified j bb Load Switching Capabilities and ...

Page 4

Parameter and Conditions -40°C...150° unless otherwise specified j bb Operating Parameters Operating voltage (V =0V Undervoltage shutdown 5 Undervoltage restart of charge pump ( Overvoltage protection I =15 mA ...

Page 5

Diagnostic Characteristics Current sense ratio, static on-condition ILIS <1 < OUT (e.g. during de-energising of inductive loads) IN Sense current under ...

Page 6

Truth Table Normal operation Overload Short circuit to GND Overtemperature Short circuit Open load L = "Low" Level H = "High" Level Terms 3 V bIN PROFET ...

Page 7

Input circuit (ESD protection Z,IN V bIN ESD-Zener diode typ., max 15 mA; Current sense output Normal operation IS,fault ...

Page 8

Reversave Reverse battery protection Logic Signal ≥1kΩ kΩ nominal. Add battery protection in applications with recommended value ...

Page 9

Inductive load switch-off energy dissipation PROFET Energy stored in load inductance · While demagnetising load inductance, the energy dissipated in PROFET ...

Page 10

Timing diagrams Figure 1a: Switching a resistive load, change of load current in on-condition OUT 90 dV/dton 10 slc(IS) L Load 1 Load son(IS) The sense signal is not ...

Page 11

Figure 3a: Short circuit L(SCp ISfault Figure 4a: Overtemperature Reset if T < IS,fault I IS Auto Restart V OUT T j Data Sheet Figure 5a: Undervoltage ...

Page 12

Figure 6a: Current sense versus load current: [mA 2.0 1 Figure 6b: Current sense ratio k ILIS 8200 This range for the current sense ratio ...

Page 13

Package Outlines All dimensions in mm D-Pak-5 Pin: PG-TO252-5-11 Sales Code Green Product To meet the world-wide customer requirements for environmentally friendly products and to be compliant with government regulations the device is available as a green product. Green products ...

Page 14

... Revision History Version Date Changes Rev. 1.0 2007-02-21 RoHS-compliant version of BTS443P Page 1, page 13: RoHS compliance statement and Green product feature added Page 1, page 13: Change to RoHS compliant package PG-TO252-5-11 Legal disclaimer updated Data Sheet Page PROFET ® BTS 443 P Rev. 1.0, 2007-02 ...

Page 15

... Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life ...

Related keywords