ITS4142N Infineon Technologies, ITS4142N Datasheet
ITS4142N
Specifications of ITS4142N
ITS4142NTR
SP000221218
Available stocks
Related parts for ITS4142N
ITS4142N Summary of contents
Page 1
Smart High-Side Power Switch for Industrial Applications 1 Channel 200m Features Short circuit protection Current limitation Overload protection Overvoltage protection (including load dump) Undervoltage shutdown with auto- restart and hysteresis Switching inductive loads Clamp of negative voltage at ...
Page 2
Block Diagram ESD Pin Symbol OUT 1 GND Vbb 4 Voltage Overvoltage Current source protection limit V Logic Charge pump Limit for Voltage unclamped sensor Level shifter ind. loads Rectifier Logic GND 2 ...
Page 3
Maximum Ratings Parameter 25°C, unless otherwise specified j Supply voltage 2) Continuous input voltage Load current (Short - circuit current, see page 5) Current through input pin (DC) Reverse current through GND-pin Junction temperature Operating temperature Storage ...
Page 4
Electrical Characteristics Parameter -40...125 ° 15...30 V unless otherwise specified j bb Thermal Characteristics Thermal resistance @ min. footprint Thermal resistance @ 6 cm Thermal resistance, junction - soldering point Load Switching Capabilities and Characteristics ...
Page 5
Electrical Characteristics Parameter -40...125 ° 15...30 V unless otherwise specified j bb Operating Parameters Operating voltage Undervoltage shutdown Undervoltage restart Undervoltage hysteresis bb(under) bb(u rst) bb(under) Standby current = -40...85 ...
Page 6
Electrical Characteristics Parameter -40...125 ° 15...30 V unless otherwise specified j bb Input 1) Continuous input voltage Input turn-on threshold voltage Input turn-off threshold voltage Input threshold hysteresis Off state input current V 1,8 V ...
Page 7
EMC-Characteristics All EMC-Characteristics are based on limited number of sampels and no part of production test. Test Conditions: If not other specified the test circuitry is the minimal functional configuration without any external components for protection or filtering. Supply voltage: ...
Page 8
Conducted Emission Acc. IEC 61967 150 Typ. V -Pin Emission at DC-On with 150 -matching network ...
Page 9
Conducted Susceptibility Acc. 47A/658/CD IEC 62132-4 (Direct Power Injection) Direct Power Injection: Failure criteria: Typ -Pin Susceptibility at DC-On/Off Typ. V ...
Page 10
Terms OUT PROFET V IN GND GND R GND Input circuit (ESD protection The use of ESD zener diodes ...
Page 11
GND disconnect PROFET GND GND GND disconnect with GND pull OUT PROFET GND GND disconnect with charged inductive load V bb ...
Page 12
Typ. transient thermal impedance 6cm heatsink area thJA p Parameter D=0,5 D=0 D=0,1 D=0,05 D=0,02 D=0,01 D ...
Page 13
Typ. turn on time 100 µ -40 - Typ. slew rate on dV/ ...
Page 14
Typ. initial peak short circuit current limit 20V; t L(SCp 2.5 2 1.5 1 0.5 0 -40 - Typ. initial peak short circuit current ...
Page 15
Typ. input current µ 2.5 5 7.5 10 Typ. input threshold voltage 25°C IN(th ...
Page 16
Maximum allowable inductive switch-off energy, single pulse 125° jstart 2.5 J 1.5 1 0.5 0 0.2 0.4 0.6 0.8 Typ. input delay time at switch f(V ) d(Vbbon) ...
Page 17
Timing diagrams Figure 1a: Vbb turn on d(Vbbon) Figure 2a: Switching a resistive load, turn-on/off time and slew rate definition IN V OUT 90 dV/dton 10 Figure 2b: Switching a ...
Page 18
Figure 3a: Turn on into short circuit, shut down by overtemperature, restart by cooling IN V OUT Output short to GND I I L(SCp L(SCr) Heating up of the chip may require several milliseconds, depending on external conditions. ...
Page 19
... Infineon Technologies Office. Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system ...