TLE6225G Infineon Technologies, TLE6225G Datasheet
TLE6225G
Specifications of TLE6225G
SP000354574
TLE6225GINTR
TLE6225GNT
TLE6225GT
TLE6225GT
Available stocks
Related parts for TLE6225G
TLE6225G Summary of contents
Page 1
Smart Quad Low-Side Switch Features • Shorted circuit protection • Overtemperature protection • Overvoltage protection • Open Load Detection • Direct parallel control of the inputs • Inputs high or low active programmable • General fault flag • Very low ...
Page 2
Pin Description Pin Symbol 1 IN1 2 IN2 3 FAULT 4 GND 5 GND 6 GND 7 GND IN3 10 IN4 11 ENA Enable for all channels/Standby 12 OUT4 13 OUT3 14 GND 15 GND 16 GND ...
Page 3
Maximum Ratings for T Parameter Supply Voltage Continuous Drain Source Voltage (OUT1...OUT4) Input Voltage, IN1 - IN4 Input Voltage, PRG, ENA Output Load Dump Protection V With Automotive Relay Load Ω =400ms; ...
Page 4
Electrical Characteristics Parameter and Conditions ° 150 ° (unless otherwise specified) 1. Power Supply Supply Voltage Supply Current (ENA = H, Outputs ON) Supply Current ...
Page 5
The TLE 6225 quad channel low-side switch with four power DMOS stages. The power transistors are protected against short to V voltage by zenerclamp. The diagnostic logic recognises a fault condition which is indicated by a fault ...
Page 6
Diagnostic Table Operating Condition Standby Normal function Overtemperature Open load or short to ground X = not relevant *selective thermal shutdown for each channel at overtemperature Fault Distinction Open load/short to ground is recognised in OFF-state. Overtemperature as a result ...
Page 7
Typical electrical Characteristics Drain-Source on-resistance DS(ON Typical Drain- Source ON-Resistance 3,5 3 2,5 2 1,5 1 -50 -25 0 Figure 6 : Typical ON Resistance versus Junction-Temperature Channel 1-4 ...
Page 8
Timing Diagrams Power Outputs 80% 20% Application Circuit +5V VCC Py.1 Px.1 Px.2 µC e.g. C166 Px.3 Px.4 INT t OFF VS PRG TLE 6225 G ENA IN1 OUT1 IN2 OUT2 IN3 OUT3 IN4 ...
Page 9
... Infineon Technologies Components may only be used in life-support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life-support device or system affect the safety or effectiveness of that device or system. Life support devices or systems are in- tended to be implanted in the human body support and/or maintain and sustain and/or protect human life ...