ICB2FL02G Infineon Technologies, ICB2FL02G Datasheet - Page 33

no-image

ICB2FL02G

Manufacturer Part Number
ICB2FL02G
Description
IC SMART BALLAST CONTROL DSO-19
Manufacturer
Infineon Technologies
Type
Ballast Controllerr
Datasheet

Specifications of ICB2FL02G

Frequency
20 ~ 120 kHz
Current - Supply
4.2mA
Operating Temperature
-25°C ~ 125°C
Package / Case
DSO-19
Packages
PG-DSO-19
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output
-
Voltage - Supply
-
Lead Free Status / Rohs Status
 Details
Other names
ICB2FL02GINTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICB2FL02G
Manufacturer:
SANYO
Quantity:
3
Part Number:
ICB2FL02G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
ICB2FL02G
Quantity:
4 800
nd
2
Generation FL-Controller for FL-Ballasts
Functional Description
2.8
Built in Customer Test Mode Operation
nd
In order to decrease the final ballast testing time for customers, the 2
generation of ballast IC
supports an integrated built in Customer Test Mode and several functions to disable some features
and states of the IC.
2.8.1 Pre Heating Test Mode
This feature forces the IC to stay in the pre heating mode (see chapter 2.8.1.2) or to starts the ignition
immediately without any preheating (see chapter 2.8.1.1 skip pre heating). A resistor at this pin
defines the duration of the pre heating phase. Normally, the pre heating phase is in a range of 0ms up
to 2500ms set via a resistor R
= 0Ω up to 25kΩ from the RTPH pin to GND. The pre heating phase
RTPH
is skipped when the RTHP pin is set to GND. If the signal at this pin is V
> 5.0 V, the IC remains in
RTPH
the pre heating mode.
2.8.1.1
Skip the Pre Heating Phase – Set RTPH Pin to GND
The Pre Heating phase can be skipped in set the RTPH pin 11 to GND. Figure 28 shows a standard
start up with a set pre heating time via resistor at the RTPH pin 11 to GND (e.g. 8.2 kΩ this is equal to
a pre heating phase of app. 820ms). The pre heating phase can be skipped in setting the RTPH pin 11
directly to GND. In that case, the ignition is directly after the soft start phase.
Figure 29 Start UP WITHOUT Pre Heating
Figure 28 Start UP WITH Pre Heating
Preliminary Datasheet
Page 33 of 55
ICB2FL02G
V1.2

Related parts for ICB2FL02G