CS5461A-ISZ Cirrus Logic Inc, CS5461A-ISZ Datasheet - Page 14

IC ENERGY METERING 1PHASE 24SSOP

CS5461A-ISZ

Manufacturer Part Number
CS5461A-ISZ
Description
IC ENERGY METERING 1PHASE 24SSOP
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CS5461A-ISZ

Package / Case
24-SSOP
Input Impedance
30 KOhm
Measurement Error
0.1%
Voltage - I/o High
0.8V
Voltage - I/o Low
0.2V
Current - Supply
2.9mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Meter Type
Single Phase
Output Voltage Range
2.4 V to 2.6 V
Input Voltage Range
2.4 V to 2.6 V
Input Current
25 nA
Power Dissipation
500 mW
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Input Voltage
5V
Supply Voltage Range
3.135V To 5.25V
No. Of Pins
24
Filter Terminals
SMD
No. Of Channels
2
Ic Generic Number
5461
Output Current Max
1µA
Rohs Compliant
Yes
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1552 - BOARD EVAL & SOFTWARE CS5461A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1095-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
114
Part Number:
CS5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
CS5461A-ISZ
Quantity:
267
Part Number:
CS5461A-ISZR
Manufacturer:
CIRRUS
Quantity:
20 000
To generate a value for the accumulated active energy
over the last computation cycle, the active power can be
multiplied by the time duration of the computation cycle.
The apparent power is the combination of the active
power and reactive power, without reference to an im-
pedance phase angle, and is calculated by the
CS5461A using the following formula:
The apparent power is registered once every computa-
tion cycle.
4.4 Linearity Performance
The linearity of the V
surements (before calibration) will be within ±0.1% of
14
S
RMS
=
V
, I
RMS
RMS
×
, and active power mea-
I
RMS
reading over the ranges specified, with respect to the in-
put voltage levels required to cause full-scale readings
in the I
formance Specifications
Until the CS5461A is calibrated, the accuracy of the
CS5461A (with respect to a reference line-voltage and
line-current level on the power mains) is not guaranteed
to within ±0.1%. See
page 35. The accuracy of the internal calculations can
often be improved by selecting a value for the Cycle
Count Register that will cause the time duration of one
computation cycle to be equal to (or very close to) a
whole-number of power-line cycles (and N must be
greater than or equal to 4000).
RMS
and V
RMS
Section 7. System Calibration
registers. Refer to
on page 7.
CS5461A
Linearity Per-
DS661F2
on

Related parts for CS5461A-ISZ