STFPC311 STMicroelectronics, STFPC311 Datasheet - Page 18

IC CTRLR/DRVR FRONT PANEL 52PQFP

STFPC311

Manufacturer Part Number
STFPC311
Description
IC CTRLR/DRVR FRONT PANEL 52PQFP
Manufacturer
STMicroelectronics
Datasheet

Specifications of STFPC311

Display Type
Vacuum Fluorescent (VF)
Interface
Serial
Current - Supply
5mA
Voltage - Supply
3 V ~ 33.3 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
52-MQFP, 52-PQFP
For Use With
497-8394 - BOARD DEMO STFPC311/ST72264497-6454 - BOARD EVAL BASED ON STFPC311
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Configuration
-
Digits Or Characters
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STFPC311
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
STFPC311
Manufacturer:
ST
0
Part Number:
STFPC311BTR
Manufacturer:
TI
Quantity:
200
Part Number:
STFPC311BTR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
STFPC311BTR
Manufacturer:
ST
Quantity:
4 000
Part Number:
STFPC311BTR
Manufacturer:
ST
0
Part Number:
STFPC311BTR
Manufacturer:
ST
Quantity:
20 000
6 Commands
6
6.1
Table 3.
Note:
18/39
Commands
A command sets the display mode and status of the VFD driver. The first 1-byte input to the
STFPC311 through the D
set to high while commands/data are transmitted, the serial communication is initialized and the
commands/data being transmitted are invalid (however, the commands/data already
transmitted remain valid).
Configuration mode setting command
This command initializes the STFPC311 and performs any one of the following functions see
Figure 14.
Figure 14. STFPC311 Configuration mode setting command order
Based on Bit 5 through Bit 4 settings.
STFPC311 Configuration mode bit 3 through bit 0 settings
a)
b)
c)
d)
Selects the number of segments and number of grids (1/8 to 1/16 duty, 12 segments
to 20 segments). When this command is executed, the display is turned off. To
resume display, the Display ON command must be executed. If the same mode is
selected, nothing is performed.
Selects the remote control protocol to use.
Sets the watchdog timer. The watchdog timer is configurable from 1s to 15s or turned
off completely.
Sets the watchdog action to perform when the watchdog timer counts. Two actions
are allowed: no action, and set STBY to (logic) high level.
IN
pin after the STB pin goes low is regarded as a command. If STB is
STFPC311