ICE2A265 Infineon Technologies, ICE2A265 Datasheet - Page 20

IC OFFLINE CTRLR SMPS CM 8DIP

ICE2A265

Manufacturer Part Number
ICE2A265
Description
IC OFFLINE CTRLR SMPS CM 8DIP
Manufacturer
Infineon Technologies
Series
CoolSET®F2r
Type
Off Line Switcherr
Datasheet

Specifications of ICE2A265

Package / Case
8-DIP (0.300", 7.62mm)
Output Isolation
Isolated
Frequency Range
93 ~ 107kHz
Voltage - Input
8.5 ~ 22 V
Voltage - Output
650V
Power (watts)
52W
Operating Temperature
-40°C ~ 150°C
Output Voltage
650 V
Input / Supply Voltage (max)
22 V
Input / Supply Voltage (min)
- 0.3 V
Duty Cycle (max)
72 %
Switching Frequency
100 KHz
Supply Current
6.1 mA
Operating Temperature Range
- 40 C to + 150 C
Mounting Style
Through Hole
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Output Power
52 W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
ICE2A265IN
ICE2A265X
ICE2A265XK
ICE2A265XTIN
ICE2A265XTIN
SP000013503

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICE2A265
Manufacturer:
HOLTEK
Quantity:
3 000
Part Number:
ICE2A265
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
ICE2A265
Manufacturer:
INFINEON
Quantity:
5 913
Part Number:
ICE2A265
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
ICE2A265
Quantity:
4 800
Part Number:
ICE2A265FKLA1
Quantity:
2 000
Part Number:
ICE2A265Z
Manufacturer:
INFINEON
Quantity:
570
4.2
Parameter
4.3
Note:
Parameter
V
Junction Temperature of
Controller
Junction Temperature of
CoolMOS™
Version 2.6
Thermal Resistance
Junction-Ambient
Junction-Case
CC
Supply Voltage
Within the operating range the IC operates as described in the functional description.
Thermal Impedance (ICE2X765I and ICE2X765P2)
Operating Range
ICE2A765I
ICE2B765I
ICE2A765P2
ICE2B765P2
ICE2A380P2 R
ICE2A765I
ICE2B765I
ICE2A765P2
ICE2B765P2
ICE2A380P2 R
Symbol
V
T
T
JCon
JCoolMOS
CC
Symbol
R
R
thJA4
thJA5
thJC1
thJC2
min.
V
-25
-25
CCoff
Limit Values
20
min.
-
-
-
-
max.
21
130
150
Limit Values
max.
74
82
2.5
2.86
Unit
V
°C
°C
Unit
K/W
K/W
K/W
K/W
Remarks
Limited due to thermal shut down
of controller
Electrical Characteristics
Remarks
Free standing with no
heat-sink
CoolSET™-F2
25 Dec 2006

Related parts for ICE2A265