M29W320EB70N6E NUMONYX, M29W320EB70N6E Datasheet - Page 22

IC FLASH 32MBIT 70NS 48TSOP

M29W320EB70N6E

Manufacturer Part Number
M29W320EB70N6E
Description
IC FLASH 32MBIT 70NS 48TSOP
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W320EB70N6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
32M (4Mx8, 2Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
TSOP
No. Of Pins
48
Operating Temperature Range
-40°C To +85°C
Access Time
70ns
Memory Configuration
4M X 8, 2M X 16
Interface Type
CFI, Parallel
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-3606
497-3606

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320EB70N6E
Manufacturer:
MICRON
Quantity:
101
Part Number:
M29W320EB70N6E
Manufacturer:
Numonyx
Quantity:
23 040
Part Number:
M29W320EB70N6E
Manufacturer:
Numonyx/48
Quantity:
184
Part Number:
M29W320EB70N6E
Manufacturer:
ST
0
Part Number:
M29W320EB70N6E
Manufacturer:
ST
Quantity:
20 000
Part Number:
M29W320EB70N6E
Quantity:
96
Part Number:
M29W320EB70N6E
0
Company:
Part Number:
M29W320EB70N6E
Quantity:
27 000
Part Number:
M29W320EB70N6E.
Manufacturer:
ST
0
Part Number:
M29W320EB70N6E/E
Manufacturer:
ST
0
4.3
4.4
22/65
Read CFI Query command
The Read CFI Query Command is used to read data from the Common Flash Interface
(CFI) memory Area. This command is valid when the device is in the Read Array mode, or
when the device is in Auto Select mode.
One Bus Write cycle is required to issue the Read CFI Query Command. Once the
command is issued subsequent Bus Read operations read from the Common Flash
Interface memory Area.
The Read/Reset command must be issued to return the device to the previous mode (the
Read Array mode or Auto Select mode). A second Read/Reset command would be needed
if the device is to be put in the Read Array mode from Auto Select mode.
See
Table 27
Interface (CFI) memory area.
Program command
The Program command can be used to program a value to one address in the memory
array at a time. The command requires four Bus Write operations, the final write operation
latches the address and data, and starts the Program/Erase Controller.
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status register is never read and no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to
issue any command to abort or pause the operation. After programming has started, Bus
Read operations output the Status register content. See
details. Typical program times are given in
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs Bus Read operations will continue to output
the Status register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.
Appendix B: Common Flash Interface
and
Table 28
for details on the information contained in the Common Flash
(CFI),
Table 6
Table
23,
Section 5: Status register
Table
24,
Table
25,
Table
for more
26,

Related parts for M29W320EB70N6E