M29W320EB70N6E NUMONYX, M29W320EB70N6E Datasheet - Page 21

IC FLASH 32MBIT 70NS 48TSOP

M29W320EB70N6E

Manufacturer Part Number
M29W320EB70N6E
Description
IC FLASH 32MBIT 70NS 48TSOP
Manufacturer
NUMONYX
Series
Axcell™r
Datasheet

Specifications of M29W320EB70N6E

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
32M (4Mx8, 2Mx16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Supply Voltage Range
2.7V To 3.6V
Memory Case Style
TSOP
No. Of Pins
48
Operating Temperature Range
-40°C To +85°C
Access Time
70ns
Memory Configuration
4M X 8, 2M X 16
Interface Type
CFI, Parallel
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-3606
497-3606

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320EB70N6E
Manufacturer:
MICRON
Quantity:
101
Part Number:
M29W320EB70N6E
Manufacturer:
Numonyx
Quantity:
23 040
Part Number:
M29W320EB70N6E
Manufacturer:
Numonyx/48
Quantity:
184
Part Number:
M29W320EB70N6E
Manufacturer:
ST
0
Part Number:
M29W320EB70N6E
Manufacturer:
ST
Quantity:
20 000
Part Number:
M29W320EB70N6E
Quantity:
96
Part Number:
M29W320EB70N6E
0
Company:
Part Number:
M29W320EB70N6E
Quantity:
27 000
Part Number:
M29W320EB70N6E.
Manufacturer:
ST
0
Part Number:
M29W320EB70N6E/E
Manufacturer:
ST
0
4
4.1
4.2
Command interface
All Bus Write operations to the memory are interpreted by the Command interface.
Commands consist of one or more sequential Bus Write operations. Failure to observe a
valid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The address used for the commands changes depending on whether the memory is in 16-
bit or 8-bit mode. See either
used, for a summary of the commands.
Read/Reset command
The Read/Reset command returns the memory to its Read mode. It also resets the errors in
the Status register. Either one or three Bus Write operations can be used to issue the
Read/Reset command.
The Read/Reset command can be issued, between Bus Write cycles before the start of a
program or erase operation, to return the device to read mode. If the Read/Reset command
is issued during the time-out of a Block erase operation then the memory will take up to
10μs to abort. During the abort period no valid data can be read from the memory. The
Read/Reset command will not abort an Erase operation when issued while in Erase
Suspend.
Auto Select command
The Auto Select command is used to read the Manufacturer code, the Device code, the
Block Protection Status and the Extended memory Block Verify code. Three consecutive
Bus Write operations are required to issue the Auto Select command. The memory remains
in Auto Select mode until a Read/Reset or CFI Query command is issued.
In Auto Select mode the Manufacturer code can be read using a Bus Read operation with
A0 = V
The Device code can be read using a Bus Read operation with A0 = V
other address bits may be set to either V
The Block Protection Status of each block can be read using a Bus Read operation with A0
= V
set to either V
Inputs/Outputs DQ0-DQ7, otherwise 00h is output.
IL
, A1 = V
IL
and A1 = V
IH
IL
and A12-A20 specifying the block address. The other address bits may be
or V
IL
IH
. The other address bits may be set to either V
. If the addressed block is protected then 01h is output on Data
Table
4, or
Table
IL
or V
5, depending on the configuration that is being
IH
.
IL
or V
IH
and A1 = V
IH
.
IL
. The
21/65