Specifications of IS42S32160B-75BL

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
512M (16M x 32)
Speed
133MHz
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 70°C
Package / Case
90-BGA
Organization
16Mx32
Density
512Mb
Address Bus
15b
Access Time (max)
5.4ns
Maximum Clock Rate
133MHz
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
125mA
Pin Count
90
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S32160B-75BL
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS42S32160B-75BL-TR
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS42S32160B-75BLI
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS42S32160B-75BLI-TR
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
IS42S32160B
Integrated Silicon Solution, Inc. — www.issi.com
Rev. 00C
03/27/08
7
Mode Register Set command
(RAS#=”L”,CAS#=”L”,WE#=”L”,BS0,1 and A12-A0 =Register Data)
The mode register stores the data for controlling the various operating modes of SDRAM.The Mode Register Set
command programs the values of CAS#latency,Addressing Mode and Burst Length in the Mode register to make
SDRAM useful for a variety of different applications.The default values of the Mode Register after power-up are
undefined;therefore this command must be issued at the power-up sequence.The state of pins BS0,1 and
A12~A0 in the same cycle is the data written to the mode register.One clock cycle is required to complete the write
in the mode register (refer to the following figure).The contents of the mode register can be changed using the
same command and the clock cycle requirements during operation as long as all banks are in the idle state.