IS45S32200E-7TLA2 ISSI, Integrated Silicon Solution Inc, IS45S32200E-7TLA2 Datasheet - Page 29

no-image

IS45S32200E-7TLA2

Manufacturer Part Number
IS45S32200E-7TLA2
Description
IC SDRAM 64MBIT 143MHZ 86TSOP
Manufacturer
ISSI, Integrated Silicon Solution Inc
Type
SDRAMr

Specifications of IS45S32200E-7TLA2

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
64M (2Mx32)
Speed
143MHz
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 105°C
Package / Case
86-TSOPII
Organization
2Mx32
Density
64Mb
Address Bus
13b
Access Time (max)
8/5.5ns
Maximum Clock Rate
143MHz
Operating Supply Voltage (typ)
3.3V
Package Type
TSOP-II
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
140mA
Pin Count
86
Mounting
Surface Mount
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
IS45S32200E
POWER-DOWN
Integrated Silicon Solution, Inc. — www.issi.com
Rev. A
02/07/08
POWER-DOWN
Power-down occurs if CKE is registered LOW coincident
with a NOP or COMMAND INHIBIT when no accesses are
in progress. If power-down occurs when all banks are idle,
this mode is referred to as precharge power-down; if power-
down occurs when there is a row active in either bank, this
mode is referred to as active power-down. Entering power-
down deactivates the input and output buffers, excluding
CKE, for maximum power savings while in standby. The
device may not remain in the power-down state longer than
the refresh period (t
performed in this mode.
The power-down state is exited by registering a NOP or
COMMAND INHIBIT and CKE HIGH at the desired clock
edge (meeting t
PRECHARGE
The PRECHARGE command (see figure) is used to
deactivate the open row in a particular bank or the open
row in all banks. The bank(s) will be available for a
subsequent row access some specified time (t
the PRECHARGE command is issued. Input A10 deter-
mines whether one or all banks are to be precharged, and
in the case where only one bank is to be precharged,
inputs BA0, BA1 select the bank. When all banks are to be
precharged, inputs BA0, BA1 are treated as “Don’t Care.”
Once a bank has been precharged, it is in the idle state and
must be activated prior to any READ or WRITE com-
mands being issued to that bank.
CKS
COMMAND
). See figure below.
REF
) since no refresh operations are
CKE
CLK
All banks idle
Enter power-down mode
t
NOP
CKS
RP
Input buffers gated off
) after
PRECHARGE Command
Exit power-down mode
BA0, BA1
A0-A9
CKE
RAS
CAS
CLK
A10
WE
CS
t
HIGH - Z
CKS
NOP
DON'T CARE
BANK ADDRESS
BANK SELECT
ACTIVE
ALL BANKS
t
t
t
RCD
RAS
RC
29

Related parts for IS45S32200E-7TLA2