IS42S32200E-6BLI-TR ISSI, Integrated Silicon Solution Inc, IS42S32200E-6BLI-TR Datasheet - Page 29

no-image

IS42S32200E-6BLI-TR

Manufacturer Part Number
IS42S32200E-6BLI-TR
Description
IC SDRAM 64MBIT 166MHZ 90BGA
Manufacturer
ISSI, Integrated Silicon Solution Inc
Type
SDRAMr

Specifications of IS42S32200E-6BLI-TR

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
64M (2Mx32)
Speed
166MHz
Interface
Parallel
Voltage - Supply
3.15 V ~ 3.45 V
Operating Temperature
-40°C ~ 85°C
Package / Case
90-BGA
Organization
2Mx32
Density
64Mb
Address Bus
13b
Access Time (max)
8/5.5ns
Maximum Clock Rate
166MHz
Operating Supply Voltage (typ)
3.3V
Package Type
TFBGA
Operating Temp Range
-40C to 85C
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
160mA
Pin Count
90
Mounting
Surface Mount
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S32200E-6BLI-TR
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
IS42S32200E
POWER-DOWN
Integrated Silicon Solution, Inc. — www.issi.com —
Rev. 00D
06/02/08
POWER-DOWN
Power-down occurs if CKE is registered LOW coincident
with a NOP or COMMAND INHIBIT when no accesses are
in progress. If power-down occurs when all banks are idle,
this mode is referred to as precharge power-down; if power-
down occurs when there is a row active in either bank, this
mode is referred to as active power-down. Entering power-
down deactivates the input and output buffers, excluding
CKE, for maximum power savings while in standby. The
device may not remain in the power-down state longer than
the refresh period (64ms) since no refresh operations are
performed in this mode.
The power-down state is exited by registering a NOP or
COMMAND INHIBIT and CKE HIGH at the desired clock
edge (meeting t
PRECHARGE
The PRECHARGE command (see figure) is used to
deactivate the open row in a particular bank or the open
row in all banks. The bank(s) will be available for a
subsequent row access some specified time (t
the PRECHARGE command is issued. Input A10 deter-
mines whether one or all banks are to be precharged, and
in the case where only one bank is to be precharged,
inputs BA0, BA1 select the bank. When all banks are to be
precharged, inputs BA0, BA1 are treated as “Don’t Care.”
Once a bank has been precharged, it is in the idle state and
must be activated prior to any READ or WRITE com-
mands being issued to that bank.
CKS
COMMAND
). See figure below.
CKE
CLK
All banks idle
Enter power-down mode
t
NOP
CKS
RP
Input buffers gated off
) after
1-800-379-4774
PRECHARGE Command
Exit power-down mode
BA0, BA1
A0-A9
CKE
RAS
CAS
CLK
A10
WE
CS
t
HIGH - Z
CKS
NOP
DON'T CARE
BANK ADDRESS
BANK SELECT
ACTIVE
ALL BANKS
t
t
t
RCD
RAS
RC