88-00144-00 Murata Wireless Solutions, 88-00144-00 Datasheet

no-image

88-00144-00

Manufacturer Part Number
88-00144-00
Description
Zigbee / 802.15.4 Modules Hi Pwr Zigbee Module SN3021
Manufacturer
Murata Wireless Solutions
Datasheet

Specifications of 88-00144-00

Rohs
yes
Frequency Band
2.4 GHz to 2.5 GHz
Sensitivity
- 103 dBm
Operating Supply Voltage
2.4 V to 3.4 V
Supply Current Transmitting
160 mA
Supply Current Receiving
35 mA
Output Power
20 dBm
Antenna Connector Type
External
Maximum Operating Temperature
+ 85 C
Dimensions
27.2 mm x 14.75 mm x 2.9 mm
Minimum Operating Temperature
- 40 C
SyChip SN3021
IEEE802.15.4/ZigBee
Smart Energy Module
User Manual
and Datasheet
Version: 1.2
February 21, 2012
Confidential Information
Note: SyChip, Inc. reserves the right to make changes in specifications at any time and without notice. The information
furnished in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Sychip for
its use, nor any infringements of patents or other rights of third parties resulting from its use. No license is generated
under any rights of SyChip or its supporters unless specifically agreed.

Related parts for 88-00144-00

88-00144-00 Summary of contents

Page 1

... IEEE802.15.4/ZigBee Smart Energy Module Note: SyChip, Inc. reserves the right to make changes in specifications at any time and without notice. The information furnished in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Sychip for its use, nor any infringements of patents or other rights of third parties resulting from its use. No license is generated under any rights of SyChip or its supporters unless specifically agreed ...

Page 2

SYSTEM DESCRIPTIONS ..................................................................................................................................... 4 1.1 A ........................................................................................................................................................ 4 PPLICATIONS 1 ............................................................................................................................................... 4 ODULE UMMARY 1 ................................................................................................................................................... 5 LOCK IAGRAM 1.4 A ............................................................................................................................................................. 5 CRONYMS 2 MECHANICAL SPECIFICATIONS ..................................................................................................................... 6 2 .............................................................................................................................................. 6 ODULE ...

Page 3

F 1 SN3021 IGURE ODULE LOCK IGURE ODULE OP AND IDE ...................................................................................................................................... 7 IGURE ODULE OTTOM IEW IGURE ETAILED ECHANICAL F ...

Page 4

... It is based upon the IEEE 802.15.4 wireless network specification. The module can be used to develop applications supporting the ZigBee PRO Smart Energy application profile. The SN3021 module operates in the 2.4 GHz unlicensed ISM frequency band for worldwide deployment ...

Page 5

... Packet Error Rate ROHS Restriction of Hazardous Substances SPI Serial Peripheral Interface UART Universal Asynchronous Receiver-Transmitter WPAN Wireless Personal Area Network SyChip/Murata Confidential Balun PA EM357 (ZigBee IC) Balun LNA VREG OUT (1.8V) Serial Flash (8Mbit) Figure 1 SN3021 Module Block Diagram Page SPI I/F UART I/F ...

Page 6

Mechanical Specifications 2.1 Module Dimension Parameter Dimension (LxWxH) Dimension tolerances (LxWxH) 2.2 Module top and side view SyChip/Murata Confidential Typical 27.20 x 14.75 x 2.90 ±0.20 x ±0.20 x ±0.15 Figure 2 Module Top and Side View Page 6 ...

Page 7

Module bottom view SyChip/Murata Confidential Figure 3 Module Bottom View Page SN3021 User Manual 1.2 ...

Page 8

Detailed mechanical data (top view) Pin 32 Pin 1 SyChip/Murata Confidential Figure 4 Detailed Mechanical Data (top view) Page Pin 20 Pin 13 SN3021 User Manual 1.2 ...

Page 9

Module Pin-out Pin # Pin name 1 GND 2 Reserved 3 PC4/JTMS 4 PB0/IRQA 5 Reserved 6 PB6/ADC1/IRQB 7 PC1/ADC3 8 SWCLK/JTCK 9 PC0/JRST/IRQD 10 GND 11 PB5/ADC0 12 GND 13 GND 14 GND 15 GND SyChip/Murata Confidential Table ...

Page 10

Pin # Pin name 16 Antenna 17 GND 18 Reserved 19 nRESET 20 GND 21 GND 22 PA3 23 GND 24 PC6/OSC32B 25 PC7/OSC32A 26 SC1SCLK/PB3 27 Reserved 28 Reserved 29 VBATT 30 Reserved 31 PA4/ADC4 32 GND 33 PA5/ADC5/nBOOTMODE ...

Page 11

Pin # Pin name SC1MISO(s)/ 34 SC1MOSI(m)/TXD/PB1/SC1SDA SC1MOSI(s)/ 35 SC1MISO(m)/RXD/PB2/SC1SCL 36 PC2/JTDO/SWO 37 SC1nSSEL/PB4 38 PC3/JTDI 39 GND 40 GND 41 GND 42 GND 43 GND 44 GND SyChip/Murata Confidential I/O Description SPI port 1 MISO (slave)/ MOSI (master) signal, ...

Page 12

DC Electrical Specifications 3.1 Typical Power Consumption Item Sleep mode VCC = 3.0V, TAMB = 25°C Internal RC oscillator on Processor, radio, peripherals off Standby mode VCC = 3.0V, TAMB = 25°C Processor on Radio and peripherals off Receive ...

Page 13

Schmitt input High Schmitt switching threshold going threshold from low to high Output voltage for logic for standard (high current) pads Output voltage for logic (8mA)for standard (high current) pads Standard current Output Source ...

Page 14

Environmental Specifications 5.1 Absolute maximum ratings Symbol Operating temperature T op Storage temperature T st Vbatt Power supply RFin RF input power MSL Moisture Sensitivity Level RoHS Restriction of Hazardous Substances 5.2 Operation conditions Symbol Vbatt Power supply Operating ...

Page 15

Application Information 6.1 Reference connection for UART host interface Figure 5 illustrates the connections between SN3021 module and the host MCU via UART interface. A level shifter may be needed if the host UART interface level does not match ...

Page 16

Reference connection for the SPI host interface Figure 6 illustrates the connections between SN3021 module and the host MCU via SPI interface. Figure 6 SPI Host Interface Reference Diagram SyChip/Murata Confidential Power supply GPIO nRESET SCLK SC1SCLK SCS SC1nSSEL ...

Page 17

Recommended host (customer) circuit board PCB pattern Pin 32 Pin 1 Figure 7 Recommended Host (customer) PCB Pattern 6.4 Host PCB layout recommendations The SN3021 module has an footprint of onboard antenna. therefore it requires some special host PCB ...

Page 18

Figure 8 Recommended Host Circuit Board Design underneath the Module Notes recommend to use a filled via to pull RF signal out from RF pad (i.e. Pin 16 you don’t use a filled via, RF trace ...

Page 19

Assembly Information 7.1 Lead-free soldering reflow profile The lead-free solder reflow profile is recommended in the table & graph below. The profile is used to attach the module to its host PCB. The module is designed to withstand 2 ...

Page 20

Package Information 8.1 Tape and reel specification The product will be shipped in tape and reel package. (1) Dimensions of tape (Plastic tape) SyChip/Murata Confidential Figure 10 Tape Dimensions Page SN3021 User Manual 1.2 ...

Page 21

Module Marking The module will be marked using a label suitable for reflow soldering. Item A Pin Model Name MFG barcode in human readable form (includes module type, date code C and serial number) SyChip/Murata Confidential ...

Page 22

... Specifications for Low-Rate Wireless Personal Area Networks (LR-WPANs) [2] Ember, “EmberZNet API Reference: For the EM35x SoC Platform”, 120-3022-000G, October 28 2010 SyChip/Murata Confidential Table 9 Ordering Information SyChip Model Number SN3021EVK SN3021 Page SyChip Part Number 88-00144-85 88-00144-00 SN3021 User Manual 1.2 ...

Page 23

Disclaimer: Please read this notice before using the SN3021 product. Please note that the only warranty that SyChip LLC (“SyChip”) provides regarding the 1. products is its conformance to the specifications provided herein. Accordingly, SyChip shall not be responsible ...

Page 24

Aircraft equipment - Aerospace equipment - Undersea equipment - Power plant control equipment - Medical equipment - Transportation equipment (vehicles, trains, ships, etc.) - Traffic signal equipment - Disaster prevention / crime prevention equipment - Application of similar complexity ...

Related keywords