Datasheet

Specifications of 88-00143-00

Rohs
yes
Frequency Band
2.4 GHz
Sensitivity
- 103 dBm
Operating Supply Voltage
3 V
Supply Current Transmitting
175 mA
Supply Current Receiving
35 mA
Output Power
20 dBm
Antenna Connector Type
Integrated
Maximum Operating Temperature
+ 85 C
Dimensions
27.2 mm x 14.75 mm
Interface Type
I2C, SPI, UART
Minimum Operating Temperature
- 40 C
SyChip SN3020
IEEE802.15.4/ZigBee
Smart Energy Module
User Manual
and Datasheet
Version: 1.1
March 8, 2011
Confidential Information
Note: SyChip, Inc. reserves the right to make changes in specifications at anytime and without notice. The information
furnished in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Sychip for
its use, nor any infringements of patents or other rights of third parties resulting from its use. No license is generated
under any rights of SyChip or its supporters unless specifically agreed.

Related parts for 88-00143-00

88-00143-00 Summary of contents

Page 1

... IEEE802.15.4/ZigBee Smart Energy Module Note: SyChip, Inc. reserves the right to make changes in specifications at anytime and without notice. The information furnished in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Sychip for its use, nor any infringements of patents or other rights of third parties resulting from its use. No license is generated under any rights of SyChip or its supporters unless specifically agreed ...

Page 2

SYSTEM DESCRIPTIONS..................................................................................................................................... 4 1.1 A ................................................................................................................................................... 4 PPLICATIONS 1 .......................................................................................................................................... 4 ODULE UMMARY 1 .............................................................................................................................................. 5 LOCK IAGRAM 1.4 A ........................................................................................................................................................ 5 CRONYMS 2 MECHANICAL SPECIFICATIONS ..................................................................................................................... 6 2 ......................................................................................................................................... 6 ODULE IMENSION ...

Page 3

F 1 SN3020 IGURE ODULE LOCK IGURE ODULE OP AND IDE IEW ...................................................................................................................................... 7 IGURE ODULE OTTOM IEW IGURE ETAILED ECHANICAL ...

Page 4

... It is based upon the IEEE 802.15.4 wireless network specification. The module can be used to develop applications supporting the ZigBee PRO Smart Energy application profile. The SN3020 module operates in the 2.4 GHz unlicensed ISM frequency band for worldwide deployment ...

Page 5

... Packet Error Rate ROHS Restriction of Hazardous Substances SPI Serial Peripheral Interface UART Universal Asynchronous Receiver-Transmitter WPAN Wireless Personal Area Network SyChip/Murata Confidential Balun PA EM357 (ZigBee IC) Balun LNA VREG OUT (1.8V) Serial Flash (8Mbit) Figure 1 SN3020 Module Block Diagram Page SPI I/F UART I/F ...

Page 6

Mechanical Specifications 2.1 Module Dimension Parameter Dimension (LxWxH) Dimension tolerances (LxWxH) 2.2 Module top and side view SyChip/Murata Confidential Typical 27.20 x 14.75 x 2.90 ±0.20 x ±0.20 x ±0.15 Figure 2 Module Top and Side View Page 6 ...

Page 7

Module bottom view SyChip/Murata Confidential Figure 3 Module Bottom View Page SN3020 User Manual 1.1 ...

Page 8

Detailed mechanical data (top view) Pin 32 Pin 1 SyChip/Murata Confidential Figure 4 Detailed Mechanical Data (top view) Page Pin 20 Pin 13 SN3020 User Manual 1.1 ...

Page 9

Module Pin-out Pin # Pin name 1 GND 2 Reserved 3 PC4/JTMS 4 PB0/IRQA 5 Reserved 6 PB6/ADC1/IRQB 7 PC1/ADC3 8 SWCLK/JTCK 9 PC0/JRST/IRQD 10 GND 11 PB5/ADC0 12 GND 13 GND 14 GND 15 GND SyChip/Murata Confidential Table ...

Page 10

Pin # Pin name 16 Reserved 17 GND 18 Reserved 19 nRESET 20 GND 21 GND 22 PA3 23 GND 24 PC6/OSC32B 25 PC7/OSC32A 26 SC1SCLK/PB3 27 Reserved 28 Reserved 29 VBATT 30 Reserved 31 PA4/ADC4 32 GND 33 PA5/ADC5/nBOOTMODE ...

Page 11

Pin # Pin name SC1MISO(s)/ 34 SC1MOSI(m)/TXD/PB1/SC1SDA SC1MOSI(s)/ 35 SC1MISO(m)/RXD/PB2/SC1SCL 36 PC2/JTDO/SWO 37 SC1nSSEL/PB4 38 PC3/JTDI 39 GND 40 GND 41 GND 42 GND 43 GND 44 GND SyChip/Murata Confidential I/O Description SPI port 1 MISO (slave)/ MOSI (master) signal, ...

Page 12

DC Electrical Specifications 3.1 Typical Power Consumption Item Sleep mode VCC = 3.0V, TAMB = 25°C Internal RC oscillator on Processor, radio, peripherals off Standby mode VCC = 3.0V, TAMB = 25°C Processor on Radio and peripherals off Receive ...

Page 13

Schmitt input High Schmitt switching threshold going threshold from low to high Output voltage for logic for standard (high current) pads Output voltage for logic (8mA)for standard (high current) pads Standard current Output Source ...

Page 14

Environmental Specifications 5.1 Absolute maximum ratings Symbol Operating temperature T op Storage temperature T st Vbatt Power supply RFin RF input power MSL Moisture Sensitivity Level RoHS Restriction of Hazardous Substances 5.2 Operation conditions Symbol Vbatt Power supply Operating ...

Page 15

Application Information 6.1 Reference connection for UART host interface Figure 5 illustrates the connections between SN3020 module and the host MCU via UART interface. A level shifter may be needed if the host UART interface level does not match ...

Page 16

Reference connection for the SPI host interface Figure 6 illustrates the connections between SN3020 module and the host MCU via SPI interface. Figure 6 SPI Host Interface Reference Diagram SyChip/Murata Confidential Power supply GPIO nRESET SCLK SC1SCLK SCS SC1nSSEL ...

Page 17

Recommended host (customer) circuit board PCB pattern Pin 32 Pin 1 Figure 7 Recommended Host (customer) PCB Pattern 6.4 Host PCB layout recommendations The SN3020 module has an onboard antenna therefore it requires some special host PCB layout underneath ...

Page 18

Zone2 GND GND Figure 8 Recommended Host Circuit Board Design underneath the Module Notes: 1. Due to the surface mount antenna on the module, the area in ‘Zone1’ on all layers of the customer circuit board should be free of ...

Page 19

Location in x-y plane Antenna Connector Antenna Shield Case Figure 9 Recommended Locations in xy-plane Figure 10 Locations Not Recommended in xy-plane 6.5.2 Location in z-plane Module Metal Figure 12 Locations Not Recommended in xy-plane SyChip/Murata Confidential No GND ...

Page 20

Assembly Information 7.1 Lead-free soldering reflow profile The lead-free solder reflow profile is recommended in the table & graph below. The profile is used to attach the module to its host PCB. The module is designed to withstand 2 ...

Page 21

Package Information 8.1 Tape and reel specification The product will be shipped in tape and reel package. (1) Dimensions of tape (Plastic tape) (2) Dimensions of reel SyChip/Murata Confidential Figure 14 Tape Dimensions TBD Page SN3020 ...

Page 22

Module marking The module will be marked using a label suitable for reflow soldering. Item A Pin Model Name MFG barcode in human readable form (includes module type, date code C and serial number) D Certification ...

Page 23

... SN3020 module in a product is not required to obtain a new FCC authorization for the module, this does not preclude the possibility that some other form of authorization or testing may be required for that end product. SyChip/Murata Confidential Table 9 Ordering Information SyChip Model Number SN3020EVK SN3020 88-00143-00/01* Page SyChip Part Number 88-00143-85 SN3020 User Manual 1.1 ...

Page 24

This device using the integrated antenna has been tested to comply with FCC CFR Part 15. The device meets the requirements for modular transmitter approval as detailed in the FCC public notice DA00.1407.transmitter given the following conditions: • User must ...

Page 25

To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operations at closer distances than this ...

Page 26

... Plano, TX 75093 USA Tel: (972) 202-8900 Fax: (972) 633-0327 Note: SyChip, Inc is an operating unit within Murata Wireless Solutions 13 References [1] IEEE Standard 802.15.4 – 2003 Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (LR-WPANs) [2] Ember, “ ...