Specifications of LCMXO2-4000HE-DSIB-EVN

Rohs
yes
Product
Evaluation Boards
Tool Is For Evaluation Of
LCMXO2-4000
Interface Type
Parallel, Serial
Operating Supply Voltage
5 V
Description/function
MachXO2 Dual Sensor Interface Board
Dimensions
113 mm x 65 mm
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
0 C
Factory Pack Quantity
1
For Use With
LFE3-70EA-HDR60-DKN
MachXO2 Dual Sensor Interface Board
Lattice Semiconductor
User’s Guide
CAUTION: The devices on the board can be damaged by improper handling.
The devices on the MachXO2 Dual Sensor Interface Board contain fairly robust ESD (Electro Static Discharge)
protection structures within them, able to withstand typical static discharges (see the “Human Body Model” specifi-
cation for an example of ESD characterization requirements). Even so, the devices are static sensitive to conditions
that exceed their designed-in protection. For example: higher static voltages, as well as lower voltages with lower
series resistance or larger capacitance than the respective ESD specifications can potentially damage or degrade
the devices on the evaluation board.
It is recommended that you wear an approved and functioning grounded wrist strap at all times while handling the
evaluation board when it is removed from the static shielding bag. If you will not be using the board for an extended
period of time, it is best to store it in the static shielding bag. Please save the static shielding bag and packing box
for future storage of the board when it is not in use.
Before connecting the DSIB to the HDR-60 Base Board, attach a cable from chassis ground on grounded test
equipment to GND on the board. Connecting the board ground to test equipment chassis ground will decrease the
risk of ESD damage to the I/O on the board as the initial connections to the board are made. Likewise, when
unplugging cables from the evaluation board, the last connection unplugged, should be the chassis GND connec-
tion to the evaluation board GND. If you have a signal source that is floating with respect to chassis GND, attempt
to neutralize any static charge on that signal source prior to attaching it to the evaluation board.
If you are holding or carrying the board when it is not in a static shielding bag, keep your finger on the corners of
the board. This will keep the board at the same voltage potential as your body until you can put the board back in
the static shielding bag.
Electrical, Mechanical, and Environmental Specifications
The nominal board dimensions are 113 mm x 65 mm (4.4375” x 2.5625”). The environmental specifications are as
follows:
• Operating temperature: 0°C to 55°C
• Storage temperature: -40°C to 75°C
• Humidity: <95% without condensation
• 5V DC power