MAXREADERKIT-EUR Cypress Semiconductor, MAXREADERKIT-EUR Datasheet - Page 22

no-image

MAXREADERKIT-EUR

Manufacturer Part Number
MAXREADERKIT-EUR
Description
Memory IC Development Tools MaxReader Dev Kit (Tuned to Europe)
Manufacturer
Cypress Semiconductor
Datasheet

Specifications of MAXREADERKIT-EUR

Rohs
yes
Product
Development Kit
Tool Is For Evaluation Of
WM72016
Memory Size
16 Kbit
Memory Type
F-RAM with Gen-2 RFID
Operating Supply Voltage
5 V
Interface Type
DSPI Serial
Factory Pack Quantity
1
Syntax
Function
Parameters
Cmd Reply
Description
4.2.4 G2CQRY: Gen2 Continuous Tag Query – Single RF Channel
G2CQRY {Q} {sel} {session} {target} {M}
Perform a continuous tag query over a single RF channel
NOTES:
1. The actual number of EPC words returned is defined in the Protocol Control word. The number of
words can be any value between 0 and 6. The shown configuration (number of words = 6) is typical.
Refer to the G2WRITEEPC command (section 4.4.3) for detail on the defined number of EPC data
words.
2. The PC and CRC words are delimited from the EPC identifier with underscore characters.
3. No response is returned if a tag query fails.
This mode performs a continuous tag query function on a single RF channel. When a tag is
successfully queried, the EPC identifier is displayed on the terminal and the buzzer will output a short
high-pitched chirp (if enabled).
The current RF channel is either the last retained RF channel from one of the two RF channel
scanning query modes or manually set through the RFCHAN command. The current RF channel
may be read through the following direct debug command:
The returned value will be a value between 1 (0x01) and 50 (0x32).
The continuous query scanning mode is terminated by either pressing the escape <ESC> key, space
bar, or ENTER key a single time. This mode must be terminated prior to executing other Gen2
commands. When the continuous query mode is terminated, the RF will remain enabled.
Parameter
Q
sel
session
target
M
Parameter
aaaa
bbbb
cccc
dddd
eeee
ffff
gggg
hhhh
:aaaa_bbbbccccddddeeeeffffgggg_hhhh
R 7A
Value (hex)
0-F
0-4
0-3
0-1
0-3
Definition
EPC Protocol Control word (PC)
EPC word 0
EPC word 1
EPC word 2
EPC word 3
EPC word 4
EPC word 5
EPC CRC
Definition
Slot count parameter (default Q=0)
Gen2 Query command sel parameter (default sel=0)
Gen2 Query command session parameter (default session=2)
Gen2 Query command target parameter (default target=0)
Gen2 Query command M parameter (default M=0)
MaxReader CLI User Guide v1.05
~
2 2
~

Related parts for MAXREADERKIT-EUR