TJA1022TK,118 NXP Semiconductors, TJA1022TK,118 Datasheet - Page 7

no-image

TJA1022TK,118

Manufacturer Part Number
TJA1022TK,118
Description
LIN Transceivers DUAL LIN 5-18V
Manufacturer
NXP Semiconductors
Datasheet

Specifications of TJA1022TK,118

Rohs
yes
Operating Supply Voltage
5 V to 18 V
Supply Current
10 mA
Package / Case
HVSON-14
Mounting Style
SMD/SMT
Factory Pack Quantity
6000
NXP Semiconductors
TJA1022
Product data sheet
7.2.3 Standby mode
7.2.4 Reset mode
If a remote wake-up event (see
associated transceiver will switch to Standby mode. A wake-up initiated by the
microcontroller (SLPx_N HIGH for t
Normal mode while the other transceiver remains in its current state.
Standby mode is an intermediate mode between Sleep and Normal modes. A transceiver
will switch from Sleep mode to Standby mode in response to a LIN bus wake-up event.
Pin RXDx will go low to indicate to the microcontroller the source of the remote wake-up
(LIN1 or LIN2). A transceiver will switch from Standby to Normal mode if the
microcontroller holds SLPx_N HIGH for t
When the TJA1022 is in Reset mode, all input signals are ignored and all output drivers
are off. The TJA1022 switches to Reset mode when the voltage on V
LOW-level power-on reset threshold, V
HIGH-level power-on reset threshold, V
Table 4.
[1]
[2]
[3]
[4]
Mode
Reset
Sleep x
Standby x
Normal x
Both transceivers enter Sleep mode after a power-on reset (e.g. after switching on V
The appropriate transceiver will switch automatically to Standby x mode if a remote LINx wake-up event is
detected in Sleep x mode.
RXDx will be LOW to indicate the source of the remote wake-up request; RXDx will go HIGH in response to
a positive edge on pin SLPx_N.
A positive edge on SLPx_N will trigger a transition to Normal mode; the transmitter will be off if TXDx is
LOW and will be enabled as soon as TXDx goes HIGH.
[1]
[2]
Operating modes
SLPx_N
x
0
0
1
All information provided in this document is subject to legal disclaimers.
RXDx
floating
floating
LOW
HIGH: recessive
LOW: dominant
Rev. 1 — 30 March 2012
[3]
Figure
gotonorm
th(POR)L
4) is detected on either of the LIN bus lines, the
th(POR)H
gotonorm
) will cause the relevant transceiver to switch to
Transmitter x
off
off
off
on/off
. When the voltage on V
, the transceivers switch to Sleep mode.
.
[4]
Dual LIN 2.2/SAE J2602 transceiver
Description
all inputs ignored; all output
drivers off
no wake-up request detected
remote wake-up request
detected
bus signal shaping enabled
BAT
BAT
TJA1022
© NXP B.V. 2012. All rights reserved.
BAT
drops below the
rises above the
).
7 of 26