MAX3107ETG/V+ Maxim Integrated, MAX3107ETG/V+ Datasheet - Page 46

no-image

MAX3107ETG/V+

Manufacturer Part Number
MAX3107ETG/V+
Description
UART Interface IC UART
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX3107ETG/V+

Number Of Channels
1
Data Rate
24 Mbps
Supply Voltage - Max
3.6 V
Supply Voltage - Min
1.71 V
Supply Current
4 mA
MAX3107
46
Figure 19. Burst Write Sequence
Figure 20. Read Byte Sequence
SPI/I
Figure 18. Write Byte Sequence
2) The master sends the 7-bit slave ID plus a write bit (low).
3) The addressed slave asserts an ACK on the data
4) The master sends the 8-bit register address.
5) The slave asserts an ACK on the data line only if the
6) The master sends 8 bits of data.
7) The slave asserts an ACK on the data line.
8) Repeat steps 6 and 7 N - 1 times.
9) The master generates a STOP condition.
line.
address is valid (NACK if not).
2
C UART with 128-Word FIFOs
BURST WRITE
S
READ SINGLE BYTE
WRITE SINGLE BYTE
FROM MASTER TO STAVE
Sr
S
S
FROM MASTER TO STAVE
FROM MASTER TO STAVE
DEVICE SLAVE ADDRESS - W
DEVICE SLAVE ADDRESS - W
DEVICE SLAVE ADDRESS - R
DEVICE SLAVE ADDRESS - W
8 DATA BITS - 1
8 DATA BITS
FROM SLAVE TO MASTER
FROM SLAVE TO MASTER
FROM SLAVE TO MASTER
A
A
A
A
A
A
With this operation the master sends an address and
receives 1 or 2 data bytes from the slave device
(Figure 20). The read byte procedure is as follows:
1) The master sends a START condition.
2) The master sends the 7-bit slave ID plus a write bit (low).
3) The addressed slave asserts an ACK on the data line.
4) The master sends the 8-bit register address.
5) The active slave asserts an ACK on the data line only
6) The master sends a repeated START (Sr).
REGISTER ADDRESS
if the address is valid (NACK if not).
P
8 DATA BITS - N
8 DATA BITS - 2
REGISTER ADDRESS
REGISTER ADDRESS
8 DATA BITS
A
A
A
NA
A
A
P
P
Single-Byte Read
Maxim Integrated