MAX1033BEUP/GG8 Maxim Integrated, MAX1033BEUP/GG8 Datasheet - Page 24

no-image

MAX1033BEUP/GG8

Manufacturer Part Number
MAX1033BEUP/GG8
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1033BEUP/GG8

Number Of Channels
4/2
Architecture
SAR
Conversion Rate
115 KSPs
Resolution
14 bit
Input Type
Single-Ended/Differential
Snr
85 dB
Interface Type
SPI
Operating Supply Voltage
4.75 V to 5.25 V
Maximum Power Dissipation
879 mW
Number Of Converters
1
Voltage Reference
4.096 V
8- and 4-Channel, ±3 x V
Multirange Inputs, Serial 14-Bit ADCs
The slowest maximum throughput rate is achieved with
the external acquisition method. SCLK controls the acqui-
sition of the analog signal in external acquisition mode,
facilitating precise control over when the analog signal is
captured. The internal clock controls the conversion of
the analog input voltage. The analog input sampling
instant is at the falling edge of the 16th SCLK (Figure 3).
For the external acquisition mode, CS must remain low
for the first 15 clock cycles and then rise on or after the
falling edge of the 16th clock cycle as shown in Figure
3. For optimal performance, idle DIN and SCLK during
the conversion. With careful board layout, transitions at
DIN and SCLK during the conversion have a minimal
impact on the conversion result.
After the conversion is complete, SSTRB asserts high
and CS can be brought low to read the conversion
result. SSTRB returns low on the rising SCLK edge of
the subsequent start bit.
In internal clock mode, the internal clock controls both
acquisition and conversion of the analog signal. The inter-
nal clock starts approximately 100ns to 400ns after the
falling edge of the eighth SCLK and has a rate of about
4.5MHz. The analog input sampling instant occurs at the
falling edge of the 11th internal clock signal (Figure 4).
For the internal clock mode, CS must remain low for the
first seven SCLK cycles and then rise on or after the
falling edge of the eighth SCLK cycle. After the conver-
sion is complete, SSTRB asserts high and CS can be
brought low to read the conversion result. SSTRB returns
low on the rising SCLK edge of the subsequent start bit.
As shown in Table 8, set M[2:0] = 100 to reset the
MAX1032/MAX1033 to its default conditions. The default
conditions are full power operation with each channel
configured for ±3 x V
sions using external clock mode (mode 0).
Table 8. Mode-Control Bits M[2:0]
24
M2
______________________________________________________________________________________
0
0
0
0
1
1
1
1
M1
External Acquisition Mode (Mode 1)
0
0
1
1
0
0
1
1
REF
Internal Clock Mode (Mode 2)
, bipolar, single-ended conver-
M0
0
1
0
1
0
1
0
1
External Clock (DEFAULT)
External Acquisition
Internal Clock
Reserved
Reset
Reserved
Partial Power-Down
Full Power-Down
Reset (Mode 4)
REF
As shown in Table 8, when M[2:0] = 110, the device
enters partial power-down mode. In partial power-
down, all analog portions of the device are powered
down except for the reference voltage generator and
bias supplies.
To exit partial power-down, change the mode by issu-
ing one of the following mode-control bytes (see the
Mode Control section):
• External-Clock-Mode Control Byte
• External-Acquisition-Mode Control Byte
• Internal-Clock-Mode Control Byte
• Reset Byte
• Full Power-Down-Mode Control Byte
This prevents the MAX1032/MAX1033 from inadvertent-
ly exiting partial power-down mode because of a CS
glitch in a noisy digital environment.
When M[2:0] = 111, the device enters full power-down
mode and the total supply current falls to 1µA (typ). In
full power-down, all analog portions of the device are
powered down. When using the internal reference,
upon exiting full power-down mode, allow 10ms for the
internal reference voltage to stabilize prior to initiating a
conversion.
To exit full power-down, change the mode by issuing
one of the following mode-control bytes (see the Mode
Control section):
• External-Clock-Mode Control Byte
• External-Acquisition-Mode Control Byte
• Internal-Clock-Mode Control Byte
• Reset Byte
• Partial Power-Down-Mode Control Byte
MODE
Partial Power-Down Mode (Mode 6)
Full Power-Down Mode (Mode 7)

Related parts for MAX1033BEUP/GG8