MAX1363EUB Maxim Integrated, MAX1363EUB Datasheet - Page 13

no-image

MAX1363EUB

Manufacturer Part Number
MAX1363EUB
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1363EUB

Number Of Channels
4/2
Architecture
SAR
Conversion Rate
133 KSPs
Resolution
12 bit
Input Type
Single-Ended/Differential
Snr
Yes
Interface Type
I2C, Serial
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Package / Case
uMAX
Maximum Power Dissipation
444.4 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
4.096 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1363EUB+
Manufacturer:
MAXIM/美信
Quantity:
20 000
unsuccessful data transfers. An unsuccessful data trans-
fer happens if a receiving device is busy or if a system
fault has occurred. In the event of an unsuccessful data
transfer, the bus master reattempts communication at a
later time.
The MAX1363/MAX1364 have a 7-bit I
address. The slave address is selected using A0. The
MAX1363/MAX1364 (EUB, MEUB, and LEUB) have
three base address options, allowing up to six devices
concurrently per I
The MAX1363/MAX1364 continuously wait for a START
condition followed by its slave address. When the device
recognizes its slave address, it is ready to accept or
send data depending on the R/W bit (Figure 6).
Figure 6. MAX1363/MAX1364 Slave Address Byte
Table 1. I
Figure 7. F/S-Mode to HS-Mode Transfer
4-Channel, 12-Bit System Monitors with Programmable
A0 STATE
High
High
Low
Low
2
SDA
SCL
C Slave Selection Table
S
SDA
SCL
2
______________________________________________________________________________________
C bus (see Table 1).
S
0
SUFFIX
MEUB
MEUB
EUB
EUB
0
1
0
Trip Window and SMBus Alert Response
1
2
0
Slave Address
HS-MODE MASTER CODE
1
ADDRESS
0110100
0110101
0110111
0110110
3
0
SLAVE ADDRESS
2
C slave
F/S MODE
0
1
4
1
X
5
At power-up, the MAX1363/MAX1364 bus timing is set
for fast mode (F/S mode, up to 400kHz I
limits the conversion rate to approximately 22ksps.
Switch to high-speed mode (HS mode, up to 1.7MHz
I
The MAX1363/MAX1364 convert up to 133ksps in moni-
tor mode, regardless of I
are unread, I
the Monitor Mode section).
Select HS mode by addressing all devices on the bus
with the HS-mode master code 0000 1XXX (X = don’t
care). After successfully receiving the HS-mode master
code, the MAX1363/MAX1364 issue a NACK, allowing
SDA to be pulled high for one clock cycle (Figure 7).
After the NACK, the MAX1363/MAX1364 operate in HS
mode. Send a repeated START (Sr) followed by a slave
address to initiate HS-mode communication. If the mas-
ter generates a STOP condition, the MAX1363/
MAX1364 return to F/S mode. Use a repeated START
condition (Sr) in place of a STOP condition to leave the
bus active and the mode unchanged.
2
C clock) to achieve conversion rates up to 94.4ksps.
0
X
6
0
X
2
7
C bandwidth limitations do not apply (see
R/W
NACK
8
2
C mode. If conversion results
ACK
Sr
9
HS MODE
2
C clock), which
HS I
2
C Mode
13