LUCL9216AGF-D AGERE [Agere Systems], LUCL9216AGF-D Datasheet - Page 12

no-image

LUCL9216AGF-D

Manufacturer Part Number
LUCL9216AGF-D
Description
Short-Loop Ringing SLIC with Ground Start
Manufacturer
AGERE [Agere Systems]
Datasheet
Short-Loop Ringing SLIC with Ground Start
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Note: The IC can be damaged unless all ground connections are applied before, and removed after, all other connections. Furthermore, when
Table 4. Recommended Operating Characteristics
Table 5. Thermal Characteristics
1. This parameter is not tested in production. It is guaranteed by design and device characterization.
2. Airflow, PCB board layers, and other factors can greatly affect this parameter.
12
dc Supply (V
Battery Supply (V
Battery Supply (V
Logic Input Voltage
Logic Output Voltage
Operating Temperature Range
Storage Temperature Range
Relative Humidity Range
PT or PR Fault Voltage (dc)
PT or PR Fault Voltage (10 x 1000 s)
Ground Potential Difference (BGND to AGND)
5 V dc Supplies (V
3 V dc Supplies (V
High Office Battery Supply (V
Auxiliary Office Battery Supply (V
Operating Temperature Range
Thermal Protection Shutdown (T
28-pin PLCC Thermal Resistance Junction to Ambient (
48-pin MLCC Thermal Resistance Junction to Ambient (
Natural Convection 2S2P Board
Natural Convection 2S0P Board
Wind Tunnel 100 Linear Feet per Minute (LFPM) 2S2P Board
Wind Tunnel 100 Linear Feet per Minute (LFPM) 2S0P Board
powering the device, the user must guarantee that no external potential creates a voltage on any pin of the device that exceeds the
device ratings. For example, inductance in a supply lead could resonate with the supply filter capacitor to cause a destructive overvoltage.
CC
Parameter
)
BAT1
BAT2
CC
CC
Parameter
)
)
)
)
Parameter
BAT1
jc
)
BAT2
)
1
)
(@ T
A
= 25 °C)
3.13
Min
–60
–12
–40
V
V
Symbol
PT
PT
JA
JA
, V
, V
)
Typ
)
–70
2
5.0
3.3
25
1, 2
:
PR
PR
V
V
BAT
BAT
–0.5
–0.5
–0.5
Min
–40
–40
5
V
Max
5.25
– 15
–75
– 5
85
BAT1
Min
150
Typ
Unit
35.5
50.5
31.5
42.5
Typ
165
°C
38
V
V
V
V
V
V
September 2001
CC
CC
V
Max
Max
–80
125
150
Agere Systems Inc.
7.0
15
±1
BAT1
95
3
+ 0.5
+ 0.5
Unit
C/W
C/W
C/W
C/W
C/W
Unit
°C
°C
C
%
V
V
V
V
V
V
V
V

Related parts for LUCL9216AGF-D